Page 1
Undercounter, Prep Table and Low Boy Refrigerators and Freezers Installation, Use & Care Manual This manual is updated as new information and models are released. Visit our website for the latest manual. www.manitowocfsg.com America’s Quality Choice in Refrigeration Part Number 14514 2/08...
Safety Notices As you work on Manitowoc equipment, be sure to pay close attention to the safety notices in this manual. Disregarding the notices may lead to serious injury and/ or damage to the equipment. Throughout this manual, you will see the following types of safety notices: Warning Text in a Warning box alerts you to a potential...
UNDERCOUNTER REFRIGERATORS AND FREEZERS Refrigerated Undercounters — Solid Door Glass Door R-6E RS-6E RSC-6E R-10E RS-10E RSC-10E Freezer Undercounter Units F-6E FS-6E FSC-6E Part Number 14514 2/08 Section 1 General Information WORK TABLES STA-10-RSE STSA-10-RSE LTA-10-RSE P-15-12 P-15-16 STA-20-RSE STSA-20-RSE LTA-20-RSE ST-59-3...
6D - 6 Drawers Work Tables Only A - Aluminum interior S - Stainless steel interior Section 1 R - Refrigerator S - Self-contained E - Series LT - Galvanized flat top ST - Stainless steel “V” edge top Part Number 14514 2/08...
Section 1 PIZZA PREP TABLE EXAMPLE Part Number 14514 2/08 Model Prefix PT–A–2 PT - Pizza Top Table A - Aluminum Interior A - Stainless Steel Interior General Information Body Type 1 - 1 Door 2 - 2 Door 3 - 3 Door...
To ensure warranty coverage, a qualified service company, authorized by McCall, must perform the warranty repair. If the dealer the McCall cabinet was purchased from does not perform warranty service, please contact the McCall Service Department for assistance. Section 1 Part Number 14514 2/08...
Front View PIZZA TABLES AND REFRIGERATED BASES Front View Cabinet Clearances (Typical Single Door Cabinet Shown) Part Number 14514 2/08 Section 2 Installation Instructions Pre-installation Checklist Install the cabinet in an indoor environment only.
5. Re-check the cabinet from side to side and from front to rear with the level. Section 2 Thread Leveling Leg into Base of Cabinet Thread Foot in as Far as Possible SV1342 Part Number 14514 2/08...
Four shelf clips are required for each shelf. Make sure that the clips are level side-to-side and front-to-rear. Place one shelf on each set of clips. Shelf Installation Part Number 14514 2/08 Installation Instructions TRAY SLIDES (OPTIONAL) Refrigerated pizza tables include a chrome plated steel pan or tray rack (Model RA-11-T) behind one door opening on 2- and 3-door models.
Failure to follow this warning could result in serious injury or death. After the power source has been connected, turn on the SER.4 main power switch. The switch is located on the cabinet top, behind the front louvered panel. Section 2 Warning Part Number 14514 2/08...
1. Grasp the knob in the center of the inner dial. 2. Turn it counterclockwise to rotate the outer dial. 3. Line up the current time of day on the outer dial with the pointer. Section 2 Part Number 14514 2/08...
0°F in freezers. The temperature variance is 6-8 degrees. A freezer should run between -2 to -3°F and +3 to +4°F. A refrigerator should run between +35 to +36°F and +41 to +42°F. For a different cabinet temperature setting, turn the temperature control knob or screw, located on the evaporator coil/blower housing.
Page 16
Installation Instructions Section 2 THIS PAGE INTENTIONALLY LEFT BLANK Part Number 14514 2/08...
COMPACT UNDERCOUNTER REFRIGERATOR AND FREEZERS Return Air PIZZA TABLES AND REFRIGERATOR BASES Part Number 14514 2/08 Section 3 Operation Uncovered food will dehydrate much more rapidly than covered food. For best food quality, always store in covered container.
9. Attach the door to the cabinet using the screws removed earlier. 10. Perform the “Door Hinge Adjustment” procedure above. Hinge Pin Screw Hinge Mechanism Hinge Pin Mounting Screws Removable Mechanism Hinge Removal Section 3 0302 Part Number 14514 2/08...
! Caution Do not use steel wool, caustic soap, or abrasive cleaners, as these may damage the metal finish. Part Number 14514 2/08 Section 4 Maintenance Cleaning the Condenser Coil Disconnect electric power before cleaning. Failure to follow this warning could result in serious injury or death.
To clean the pan drain outlet, gently insert a pliable wire, such as a pipe cleaner, 3-4" (7-10 cm) into the mouth of the outlet. Remove any obvious debris in the pan bottom. fin_comb Section 4 Part Number 14514 2/08...
Refrigerator is freezing product Compressor will not start — hums and trips on overload protector Part Number 14514 2/08 Section 5 Before Calling for Service Disconnect electric power before performing any service. Failure to follow this warning could result in injury or death.
Page 22
Before Calling for Service Section 5 THIS PAGE INTENTIONALLY LEFT BLANK Part Number 14514 2/08...