1) Press "ON/OFF",turn off the IR Remote;
Press "ON/OFF" again,recover to the previous state.
2) When in OFF state, press down "9" + "8" + "7" respectively to recover factory settings.
3) Once recover the factory settings, wireless DMX is open to receive signals. Need to reset the
parameter according to your application.
Operation Instruction
1. Charging:
1)
The device equipped with a 11.1V/12AH lithium battery;
2)
Please recharge in time when the battery is in low power or out of power; if does not use this device
for long time, please charge at least once within one month, in order to prevent the lithium electricity
from causing and damaging because of excessive consumption.
3)
Lithium battery charging time should not more than 24 hours.
4)
After cycle use 300 times, battery capacity will be reduced to about 8AH(70% of the total capacity);
please reduce the charge and discharge times, to extend battery lifetime; after 300 times charging
and discharging, need to replace the battery, in order not to affect use.
5)
Lithium battery cannot separate charge take out from the device.
2. Temperature Control Protection
1) When the temperature of LED board is more than 60 Celsius degree, or the Thermistor check fails, the
device will start the high temperature protection, reduce power output automatically.
Thermistor test failures: Thermistor damaged, or the Thermistor connected abnormally, or single chip
microcomputer port damaged.
2) "Detection" and display when device power on:
When the device power off, then turning on the power supply in two seconds, the device will detect
temperature control work condition.
3) The Red Indicator Light
Two seconds prior to power, the Thermistor test failures, the red light will light up.
The Thermistor is working normally, the light is off.
4) LCD display
Press the "MODE" button and then power on. If the temperature control working normal, will display
"Check-up Tr1: xx"(xx is the current LED board temperature value); if the temperature control working
abnormal, will display "Check-up Tr1: Er".
5) In the process of using, the brightness of abnormal device is far below the normal device. Please test
the temperature condition before use.
3. Wireless DMX connection
The device using 2.4GHz wireless receiving module "Pico G4 Receiver, 2.45GHz", provided by Swedish
WIRELESS SOLUTION, with only a 2.45 GHz wireless signal receiving function. In order to match using,
please choose "Black Box F-1 G4 MK2" provided by WIRELESS SOLUTION;
The status indicator of wireless communication: through an LED indicator light display
1) No emitter matching: indicator light goes out for a long time;
2) Matching with one emitter, but loss signal communication: the indicator light will lighting for 100ms, and
then put out for 100ms, will flicker quickly.