1. Identify the wall-sleeve brand for your installation, from the chart below.
Wall Sleeve Dimensions
Brand
White-Westinghouse
Frigidaire
Carrier (52F Series)
Width
Height
25Y2
151/4
251/2
151/4
251/2
151/4
General Electric/Hotpoint
26
15%
157/'8
Whirlpool
257/'8
161/2
171/8 or 23
Fedders/Emerson
27
163/4
163/'4or 193/'4
Sears/Kenmore
253/4
167/'8
18%
Emerson/Fedders
263/4
153/4
15
Carrier (51S Series)
253/4
167/'8
18%
Friedrich
27
163/'4
163/'4
Depth
16, 171½ or22
16, 171½ or22
16, 171½ or22
® All wall sleeves used to mount the new Air Conditioner must be in sound structural condition and have a rear
grille that securely
attaches
to sleeve,
or rear flange that serves
as a stop for the Air Conditioner.
• When installation is complete, replacement
unit MUST have a rearward slope as shown in Fig.1.
2. Remove old Air Conditioner from wall sleeve and prepare wall sleeve as follows:
Clean interior (do not disturb seals).
Wall sleeve must be securely fastened in wall before installing Air Conditioner. Drive more nails or screws through
sleeve, into wall, if needed.
Retouch wall sleeve painted surface if needed.
.
If not existing, drill a 3/16" clearance hole for grounding screw through left side of wall sleeve, in a clear area about
3 inches maximum back from front edge of sleeve, using grounding screw and toothed washer. Pull loose end
of ground wire out front of sleeve, and temporarily bend it down and around lower edge of sleeve (Fig.2). This
ground wire will later be attached to frame of air conditioner once it is installed.
REAR
Walt
sleeve
1/4" to 5/16"
II
J
Watt sleeve to unit
1
3/16"
sleeve grounding
t
-
Hole
1"
Illj
/ t
Fig. 1
Fig.2