Possible
Causes
What
To Do
Air conditioner
The air conditioner
. Hake sure the air conditioner plug is pushed
does not start
is unplugged,
completely into the outlet,
The fuse is blown/circuit
. Check the house fuse/circuit
breaker box and replace
breaker is tripped,
the fuse or reset the breaker,
Power failure.
.The unit will automatically
restart in the settings last
used after the power is restored,
.There is a protective
time delay (approximately
3 minutes) to prevent tripping
of the compressor
overload,
For this reason, the unit may not start
normal
cooling for 3 minutes
after it is turned
back on,
The current
interrupter
.Press the RESETbutton located on the power cord plug,
device is tripped.
.If the RESETbutton will not stay engaged, discontinue
use of the air conditioner
and contact
a qualified
service technician,
Air conditioner
does
Airflow is restricted.
, Hake sure there are no curtains, blinds or furniture
not cool as it should
blocking the front of the air conditioner,
The temp control may
• In the Coolmode, press the Decrease - pad,
not be set correctly.
The air filter is dirty.
• Clean the filter at least every 30 days.
See the Cnre and C/e_ning section,
The room may have been hot.
. When the air conditioner
is first turned on, you need
to allow time for the room to cool down,
Cold air is escaping.
• Check for open furnace registers and cold air returns.
Cooling
coils have iced up.
.See "Air conditioner
freezing up" below.
Ice blocks the air flow
. Set the controls at High Fan or High Cooland
set the
freezing up
and stops the air conditioner
thermostat
to a higher temperature,
from cooling the room.
The remote control
The battery
is inserted
. Check the position of the battery. They should be
is not working
incorrectly,
inserted in the opposite (+) and (-) direction,
The battery
may be dead.
. Replace the battery.
Water
drips outside
Hot, humid weather.
. This is normal.
Water
drips indoors
The air conditioner
is not
. For proper water disposal, make sure the air conditioner
tilted to the outside,
slants slightly from the case front to the rear,
Water
collects
in
Moisture
removed
from air
. This is normal for a short period in areas with little
base pan
and drains into base pan.
humidity; normal for a longer period in very humid areas,
Normal
Operating
Sounds
,
You may hear u pinging noise caused by
water being picked up and thrown against the
condenser on rainy days or when the humidity
is high, This design feature helps remove
moisture and improve efficiency,
,
You may hear the thermostat click when the
compressor cycles on and off,
Water will collect in the base pan during
high humidity or on rainy days, The water
may overflow and drip from the outdoor side
of the unit,
The fan may run even when the compressor
does not,