AX3000 Platine Terminal Ethernet TCP/IP Model 80 Installation Guide January 2012 - Ref: I80E0922-2 Model AX3000/M80 Type EA...
Page 2
Fax: 33 1.69.28.82.04 Email: info@axel.com The information in this document is subject to change without notice. AXEL assumes no responsibility for any errors that may appear in this document. All trademarks and registered trademarks are the property of their respective holders.
1 - NOTICES ......................1 1.1 - SAFETY NOTICES................... 1 1.2 - EMC NOTICES..................1 1.3 - PHYSICAL SPECIFICATIONS..............2 2 - INSTALLATION ..................... 3 2.1 - DESCRIPTION ..................3 2.2 - INSTALLATION ..................4 2.2.1 - Mounting the Terminal on a Flat Screen ........... 4 a) Attaching the VESA bracket................4 b) Attaching the Terminal ..................5 c) Using the Terminal ....................6...
Page 4
The AXEL AX3000 Terminal is based on a modular concept. The AX3000 is designed and manufactured by Axel. The terminal's electronics are contained within a slim base unit which provides connections for a VGA or SVGA monitor, keyboard, system printer and...
1 - NOTICES 1.1 - SAFETY NOTICES Do not attempt to fix an AX3000 component failure by opening the terminal case. In case of hardware failure, contact your service representative. Check AC voltage from the wall outlet is compatible with the AX3000 external power.
Notices and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Installation 2 - INSTALLATION This chapter provides information and instructions to install the Axel Terminal. 2.1 - DESCRIPTION Rear Panel: Front Panel: - 1 power connector, - 1 power switch, - 1 VGA or SVGA connector, - 2 USB ports, - 2 USB Ports, - 1 green LED.
Installation 2.2 - INSTALLATION 2.2.1 - Mounting the Terminal on a Flat Screen The terminal had been designed to be mounted on the flat screen: this requires the monitor to have available the 4 VESA mounting screw holes. a) Attaching the VESA bracket With the 4 screws provided attach the bracket to the VESA mounting points on the monitor.
Installation b) Attaching the Terminal Hook the terminal to the bracket, matching the hooks with the corresponding holes: Installation Guide - Model 80...
AX3000 before connecting or disconnecting any cables. Do not plug in the AX3000 power cord until all other connectors have been plugged in. Make sure the AX3000 and monitor power switches are in the OFF (0) position before connecting cables to the back panel.
100 Mb when the light is on. e) Other USB Devices AX3000 Model 80 has four USB ports as a standard feature. These ports are located on the front and rear panels of the terminal case.
The power switch is located on the terminal front panel. The green LED on the front of the terminal should light, and a single audible beep should be heard, to indicate that the AX3000 terminal is powered up and operating correctly.
At any time pressing <Ctrl><Alt><Esc> will enter Terminal Set-Up. For more information about set-up, please read the AX3000 User's Manual. 2.1 - QUICK SET-UP The quick set-up is designed for a typical simple environment of:...
Initial Power-On The dialog box structure (referred to as a Wizard) is shown below: First Screen Network Connection Serial Connection (TCP/IP session) (RS232 session) Reboot Citrix Citrix Desktop Printer Graphical (text 5250 or (published display & 3270 application printer or server ) sessions) (TSE, VNC or Citrix with...
Page 15
AxRM (available free from www.axel.com). For more information on AxRM’s action in the auto-configuration process, see the manual "Axel Remote Management - Version 3". The auto-configuration process is automatically initiated when power is applied to a brand new terminal or if the terminal is reset to factory defaults. This process may be aborted by pressing any key.
Connector Pin Assignments 4 - CONNECTOR PIN ASSIGNMENTS This chapter describes the connector pin assignments for the different ports of the AX3000 Models 80. 4.1 - ETHERNET PORT RJ45 (NET) Recommended wiring is a non-shielded twisted-pair cable (UTP), category 3...
Connector Pin Assignments 4.2 - VIDEO INTERFACE The AX3000 video interface is VGA and SVGA compatible: VGA/SVGA connector (Models 80 rear panel) Pin Signal name Green Blue Not Connected Ground Ground Ground Ground Not Connected Ground Not Connected CRT SDA Horizontal sync.
Connector Pin Assignments 4.3 - USB PORTS AX3000 Models 80 are equipped with four USB ports. (Located on the terminal front and rear panels.) Technical specifications: - Supported speeds: - Low-speed (1,5 Mbits), - Full-speed (12 Mbits), - High-speed (480 Mbits).
5 - PROBLEM SOLVING This chapter describes some of the problems that may occur during installation of the AX3000 Models 80, and offers possible solutions. Safety Warning! Under no circumstances should you attempt to fix a Platine problem by opening the terminal case. High voltages may be present even when the terminal is switched off.
Page 20
Problem Solving This signal indicates that keyboard initialization has failed. Check the keyboard connection to the terminal back panel. It is possible for the keyboard to function correctly, despite this double-beep signal. As a quick test of keyboard operation, enter set-up mode by pressing the <Ctrl><Alt><Esc>...
Page 22
14 Avenue du Québec Bât. K2 EVOLIC - BP 728 91962 Courtabœuf cedex - FRANCE Tel.: 33 1.69.28.27.27 Fax: 33 1.69.28.82.04 Email: info@axel.com...
Need help?
Do you have a question about the AX3000 and is the answer not in the manual?
Questions and answers