Page 1
AX3000 Platine Terminal Ethernet TCP/IP Models 70 Installation Guide January 2012 - Ref: I70E0826-1 Model AX3000/M70 Type EA...
Page 2
Fax: 33 1.69.28.82.04 Email: info@axel.com The information in this document is subject to change without notice. AXEL assumes no responsibility for any errors that may appear in this document. All trademarks and registered trademarks are the property of their respective holders.
1 - NOTICES ......................1 1.1 - SAFETY NOTICES................... 1 1.2 - EMC NOTICES..................1 1.3 - PHYSICAL SPECIFICATIONS..............2 2 - INSTALLATION ..................... 3 2.1 - DESCRIPTION ..................3 2.2 - INSTALLATION ..................4 2.2.1 - Mounting the Terminal on a Flat Screen ........... 4 a) Attaching the VESA Support ................4 b) Hooking the Terminal ..................5 c) Using the Terminal ....................6...
Page 4
The AXEL AX3000 Terminal is based on a modular concept. The AX3000 is designed and manufactured by Axel. The terminal's electronics is contained within a slim base unit which provides connections for a VGA or SVGA monitor, keyboard, system printer and Ethernet...
1 - NOTICES 1.1 - SAFETY NOTICES Do not attempt to fix an AX3000 component failure by opening the terminal case. In case of hardware failure, contact your service representative. Check AC voltage from the wall outlet is compatible with the AX3000 external power.
Notices and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Installation 2 - INSTALLATION This chapter provides information and instructions to install the Axel Terminal. 2.1 - DESCRIPTION Rear Panel: Front Panel: - 1 power connector, - 1 power switch, - 1 VGA or SVGA connector, - 2 USB ports, - 1 PS/2 keyboard connector, - 1 green LED.
Installation 2.2 - INSTALLATION 2.2.1 - Mounting the Terminal on a Flat Screen The terminal had been designed to be mounted on the flat screen: this requires the monitor to have available the 4 VESA mounting screw holes. a) Attaching the VESA Support With the 4 screws provided attach the bracket to the VESA mounting points on the monitor Installation Guide - Models 70...
Installation b) Hooking the Terminal Hook the terminal to the bracket, matching the hooks with the corresponding holes: Installation Guide - Models 70...
AX3000 before connecting or disconnecting any cables. Do not plug in the AX3000 power cord until all other connectors have been plugged in. Make sure the AX3000 and monitor power switches are in the OFF (0) position before connecting cables to the back panel.
Installation a) The Monitor Plug in the VGA monitor cable to the 'SVGA' connector on the terminal rear panel. Note: when the terminal is installed in a cabinet or rack, it is essential to maintain air circulation around both the terminal and the VGA/SVGA monitor. b) The Keyboard Two keyboard types can be connected: - USB keyboard: connect it to on of the two USB ports on the terminal front...
Installation e) Other USB Devices AX3000 Model 70 has two USB ports as a standard feature. These ports are located on the front panel of the terminal case. The USB cables must be shielded and cable length must not exceed 5 meters.
At any time pressing <Ctrl><Alt><Esc> will enter Terminal Set-Up. For more information about set-up, please read the AX3000 User's Manual. 2.1 - QUICK SET-UP The quick set-up is designed for a typical simple environment of:...
Page 16
Initial Power-On The dialog box structure (referred to as a Wizard) is shown below: First Screen Network Connection Serial Connection (TCP/IP session) (RS232 session) Reboot Citrix Citrix Desktop Printer Graphical (text 5250 or (published display & 3270 application printer or server ) sessions) (TSE, VNC or Citrix with...
Page 17
AxRM (available free from www.axel.com). For more information on AxRM’s action in the auto-configuration process, see the manual "Axel Remote Management - Version 3". The auto-configuration process is automatically initiated when power is applied to a brand new terminal or if the terminal is reset to factory defaults. This process may be aborted by pressing any key.
Connector Pin Assignments 4 - CONNECTOR PIN ASSIGNMENTS This chapter describes the connector pin assignments for the different ports of the AX3000 Models 70. 4.1 - ETHERNET PORT RJ45 (NET) Recommended wiring is a non-shielded twisted-pair cable (UTP), category 3...
Connector Pin Assignments 4.2 - KEYBOARD INTERFACE The AX3000 keyboard interface is a Mini-DIN connector. To connect a keyboard which has a DIN connector, use a DIN-to-Mini-DIN adaptor: Signal name Data Ground + 5 V DC Clock Keyboard connector (Models 70 rear panel) 4.3 - MOUSE INTERFACE...
Connector Pin Assignments 4.4 - VIDEO INTERFACE The AX3000 video interface is VGA and SVGA compatible: VGA/SVGA connector (Models 70 rear panel) Pin Signal name Green Blue Not Connected Ground Ground Ground Ground Not Connected Ground Not Connected CRT SDA Horizontal sync.
Connector Pin Assignments 4.5 - USB PORTS AX3000 Models 70 are equipped with two USB ports located on the terminal front panel. Technical specifications: - Supported speeds: - Low-speed (1,5 Mbits): keyboard and mouse - Full-speed (12 Mbits): printers - Maximal consumption: 500 mA (for the both USB ports) Note: Due to potentially excessive power consumption "non-IT"...
5 - PROBLEM SOLVING This chapter describes some of the problems that may occur during installation of the AX3000 Models 70, and offers possible solutions. Safety Warning! Under no circumstances should you attempt to fix a Platine problem by opening the terminal case. High voltages may be present even when the terminal is switched off.
Page 23
Problem Solving This signal indicates that keyboard initialization has failed. Check the keyboard connection to the terminal back panel. It is possible for the keyboard to function correctly, despite this double-beep signal. As a quick test of keyboard operation, enter set-up mode by pressing the <Ctrl><Alt><Esc>...
Page 24
14 Avenue du Québec Bât. K2 EVOLIC - BP 728 91962 Courtabœuf cedex - FRANCE Tel.: 33 1.69.28.27.27 Fax: 33 1.69.28.82.04 Email: info@axel.com...