FUNAI HT2-M200 Service Manual page 18

Hide thumbs Also See for HT2-M200:
Table of Contents

Advertisement

FIRMWARE RENEWAL MODE (for User)
1. Press [SETUP] button to display Setup menu.
2. Select Custom - Others - Software Update - Disc
Update.
3. The screen appears in Fig. a when "Yes" is
chosen and the tray opens. Insert the disc and
press [ A ] button.
Software Update
Please insert a disc for software update.
If you want to exit update, press 'RETURN'.
4. Disc loading starts. Fig. b will appear on the
screen and Fig. c appears on the VFD.
Software Update
Loading Disc...
Fig. c VFD in Update Mode
5. Fig. d will appear on the screen, then select "Yes".
Fig. e will appears on the VFD.
Software Update
Current Version
Insert Version
Unit has latest Update, so Update in not needed.
Press 'RETURN' .
Yes
Fig. e VFD in Update Mode
Fig. a
Fig. b
: X.XXX
: X.XXX
No
Fig. d
6. Firmware loading starts. Fig. f will appear on the
screen and Fig. g appears on the VFD.
1. Loading
Loading Software...
If you want to exit Update, press 'RETURN'.
Fig. g VFD in Update Mode
7. Updating starts automatically. Fig. h will appear
on the screen and update progress will be
displayed as shown in Fig. i on the VFD.
1. Loading
Updating Software...
Please wait for a few minutes.
Do not unplug the AC cord or interrupt updating process.
When update is completed unit will automatically turn Off.
Update disc will eject after unit automatically turns back on.
Fig. i VFD in Update Mode
8. "GOODBYE" on the VFD and power turns off
automatically when it finishes.
9. The power turns on and the tray will open
automatically. Remove the disc on the tray.
Note: The setup setting configured before the update
will be kept.
1-7-3
Software Update
2. Updating
Fig. f
Software Update
2. Updating
Fig. h
E1T12FW