To Disable Sleep Mode On Computer (Windows Vista); Connection To Pc; Reset; Troubleshooting - Oregon Scientific WMR200 User Manual

Professional weather center
Hide thumbs Also See for WMR200:
Table of Contents

Advertisement

TO DISABLE SLEEP MODE ON COMPUTER (WINDOWS VISTA)

1. Right click on Desktop.
2. Choose "Personalize".
3. Click on "Screen Saver" Tab in the Display Properties window.
4. Click on "Change Power Settings" located at the bottom half of window.
5. Select "High Performance" and click "Change plan settings".
6. Click "Change advanced power settings".
7. Click "Sleep" and click "Hibernate after".
8. Click "Setting" and set "0" minutes.
9. Click "Apply" and then "OK".

CONNECTION TO PC

To upload the weather data to the computer:
Plug one end of the USB cable into the USB port and the other end into the
computer.
NOTE The USB is only used for uploading weather data. It cannot be used for
charging battery power.
To clear records:
1. Press clock area
until DATA LOGGER is displayed.
2. Press and hold MEM.
3. All LED icons will light up and turn off consecutively (right to left). Delete process
is complete and successful after blinking of last icon

RESET

Press RESET to return to the default settings.
TROUBLE SHOOTING
PROBLEM
SYMPTOM
Barometer
Strange readings
Calendar
Strange date / month
Clock
Cannot adjust clock
Cannot auto-synch
Temp
Shows "LL" or "HH"
Remote
Cannot locate
sensor
remote sensor

PRECAUTIONS

Do not subject the unit to excessive force, shock, dust, temperature or humidity.
Do not cover the ventilation holes with any items such s newspapers, curtains
etc.
Do not immerse the unit in water. If you spill liquid over it, dry it immediately with
a soft, lint-free cloth.
Do not clean the unit with abrasive or corrosive materials.
Do not tamper with the unit 's internal components. This invalidates the
warranty.
Only use fresh batteries. Do not mix new and old batteries.
Images shown in this manual may differ from the actual display.
When disposing of this product, ensure it is collected separately for special
treatment.
Placement of this product on certain types of wood may result in damage to its
finish for which Oregon Scientific will not be responsible. Consult the furniture
manufacturer's care instructions for information.
The contents of this manual may not be reproduced without the permission of the
manufacturer.
Do not dispose old batteries as unsorted municipal waste. Collection of such
waste separately for special treatment is necessary.
Please note that some units are equipped with a battery safety strip. Remove the
strip from the battery compartment before first use.
NOTE The technical specifications for this product and the contents of the user
manual are subject to change without notice.
NOTE Features and accessories will not be available in all countries. For more
information, please contact your local retailer.
.
REMEDY
Set unit
Change language
Disable radio-controlled clock
1.
Adjust batteries
2.
Press RESET
3.
Manually activate radio
controlled clock
Temperature is out-of-range
1.
Check batteries
2.
Check if sensors are
within range
10
SPECIFICATIONS
BASE STATION
Dimensions (L x W x H)
149 x 198 x 47 mm (5.9 x 7.8 x 1.9 inches)
Weight
510 g (18 oz) without battery
INDOOR BAROMETER
Barometer unit
mb/hPa, inHg and mmHg
Measuring range
700 – 1050mb/hPa
Accuracy
+/- 10 mb/hPa
Resolution
1mb (0.0 inHg)
Altitude setting
Sea level
User setting for compensation
Weather display
Sunny, Clear night, Partly Cloudy, Cloudy,
Cloudy at night, Rainy and Snowy
Memory
Historical data and bar chart for last 24hrs
INDOOR TEMPERATURE
Temp. unit
°C / °F
Displayed range
0°C to 50°C (32°F to 122°F)
Operating range
-30°C to 60°C (-4°F to 140°F)
Accuracy
0°C - 40°C: +/- 1°C (+/- 2.0°F)
40°C - 50°C: +/- 2°C (+/- 4.0°F)
Comfort
20°C to 25°C (68°F to 77°F)
Memory
Current, Min and Max temp.
Dew Point w/ Min and Max
Alarm
Hi / Lo
INDOOR RELATIVE HUMIDITY
Displayed range
2% to 98%
Operating range
25% to 90%
Resolution
1%
Accuracy
25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
Comfort
40% to 70%
Memory
Current, Min and Max
Alarm
Hi / Lo
RADIO-CONTROLLED / ATOMIC CLOCK
Synchronization
Auto or disabled
Clock display
HH:MM:SS
Hour format
12hr AM/PM or 24hr
Calendar
DD/MM or MM/DD
Weekday in 5 languages
(E, G, F, I, S)
Battery
4 x UM-3 (AA) 1.5V batteries
AC adapter 6V
REMOTE WIND SENSOR UNIT
Dimensions (L x W x H)
178 x 76 x 214 mm (7 x 3 x 8.4 inches)
Weight
100 g (3.53 oz) without battery
Wind speed unit
m/s, kph, mph, knots
Speed accuracy
2 m/s ~ 10 m/s (+/- 3 m/s)
10 m/s ~ 56 m/s (+/- 10%)
Direction accuracy
16 positions
Transmission of
Approx. every 14 seconds
wind speed signal
Memory
Max speed gust
Battery
2 x UM-3 (AA) 1.5V batteries
OUTDOOR TEMPERATURE / HUMIDITY UNIT
RELATIVE TEMPERATURE
Dimensions
115 x 87 x 118 mm
(L x W x H)
(4.5 x 3.4 x 4.6 inches)
Weight
130 g (4.59 oz) without battery
Temp. unit
°C / °F
Displayed range
-50°C to 70°C (-58°F to 158°F)
Operating range
-30°C to 60°C (-4°F to 140°F)
Accuracy
-20°C – 0°C: +/- 2°C (+/- 4.0°F)
0°C - 40°C: +/- 1°C (+/- 2.0°F)
40°C - 50°C: +/- 2°C (+/- 4.0°F)
50°C - 60°C: +/- 3°C (+/- 6.0°F)
Comfort
20°C to 25°C (68°F to 77°F)
Memory
Current, Min and Max temp.
Dew Point w/ Max and Min
Wind chill temp. and min
RELATIVE HUMIDITY
Displayed range
2% to 98%

Hide quick links: