EPS Bio Technology EME Quick Reference Manual

Self-monitoring blood glucose system
Hide thumbs Also See for EME:

Advertisement

EME
Self-Monitoring Blood Glucose System
Quick Reference Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EME and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EPS Bio Technology EME

  • Page 1 Self-Monitoring Blood Glucose System Quick Reference Guide...
  • Page 2: Inserting Batteries

    Inserting Batteries 1. Open the battery door on the 2. Insert two batteries and the 3. Put the battery door back in back of the meter by pushing meter beeps. place and snap it closed. the tab in the direction of the The meter turns on arrow and pulling the door up.
  • Page 3: Setting The Time And Date

    Setting The Time and Date Setting the current time and date in your meter is important if you use the meter memory. 3. Repeat step 2 to set the date and 1. Press (right button) to 2. The display shows the last time.
  • Page 4: Running A Control Solution Test

    Running a Control Solution Test You need the meter, a test strip, and control solution. 2. Press  (left button) to set 1. Put a test trip into the (AC), (PC) 3. The icons (insert meter as the direction or CS Mode, then press (right button) to strip) and (apply...
  • Page 5 4. Place the meter on a flat 7. Touch the drop to the Blood 9. Do not remove the test strip yet. surface, like a table. collection area at the tip of the Check if the reading falls within the 5.
  • Page 6: Inserting A Lancet Into The Lancing Device

    Inserting a Lancet into the Lancing Device You must first load the lancet into the lancing device to get it ready for use. 2. Insert the lancet into the lancing 1. Unscrew the Cap. 3. Recap the front cap. device firmly then twist off the protective cover.
  • Page 7 4. Select the desired penetration 5. Pull on the sliding barrel of the 6. Set the lancing device aside depth. lancing device until it clicks and until later in the test. then release. Now the lancing device is ready. Do not prick your finger until your meter and strip are prepared.
  • Page 8: Running A Blood Glucose Test With Blood From Your Fingertips

    Running a Blood Glucose Test with Blood from Your Fingertips 3. Press  (left button) to set 1. Wash your hands with 2. Put a test strip into the meter in soap and warm water. the direction of the arrow. The (AC) or (PC) Rinse and dry thoroughly.
  • Page 9 4. The icons (insert strip) 5. Hold the lancing device firmly 6. Gently squeeze and/or massage (apply blood) show against the side of your finger. your fingertip until a round drop themselves. Press the trigger button. Then of blood on your fingertip. When the blood drop flashes remove the lancing device 7.
  • Page 10 8. Touch the drop to the tip of the 9. The meter starts to count 10. Push the Strip Ejector to remove transparent window of the test down from 5 seconds and the test strip. strip. then shows the test result. 11.
  • Page 11: Running A Blood Glucose Test With Blood From Your Forearm

    Running a Blood Glucose Test with Blood from Your Forearm Please use the clear cap with the lancing device for AST testing. 1. This graphic shows where the 2. Massage the puncture area of 4. Press the trigger button to meter cleared for alternate forearm for a few seconds.
  • Page 12: Running A Blood Glucose Test With Blood From Your Palm

    Running a Blood Glucose Test with Blood from Your Palm 3. Press the trigger button to activate 1. Massage the puncture area of 2. Press and hold the device palm for a few seconds. with a clear adjustable tip the lancing device. 4.
  • Page 13: Discarding Used Lancets

    Discarding Used Lancets 3. Pointing the lancing device 1. Unscrew and remove the 2. Without touching the used toward a container for sharp or cap. lancet, stick the lancet tip biohazard material, slide the into its protective cover. ejection button up to release the covered lancet into the container.
  • Page 14: Viewing Test Results

    Viewing Test Results The meter provides 7, 14, 30 and 90 days averaging to help track your blood glucose result soundlessly. 4. Press to view averages of 1. Press (right button) until turning the meter on. 30day-AC/PC and 7/14/30/90 days. 2.
  • Page 15: Screen Messages And Troubleshooting

    Screen Messages and Troubleshooting Never make treatment decisions based on an error message. If you have any concerns, please contact your healthcare provider. Humidified/Used strips Low power System fault Action: Replace with a Action: Replace with new Action: Replace the batteries first. If new strip.
  • Page 16 System fault Test result is higher than 630 The test result is lower than 20 Action: Replace the mg/dL (35.0 mmol/L). mg/dL (1.1 mmol/L). batteries first. If Err Action: Test again. If the result is Action: Test again. If the result is still appears again, please still the same, try a control solution the same, try a control solution test...
  • Page 17 Err message. Not enough The ”Ht” and thermometer The ”Lt” and thermometer icon sample was drawn into the icon appears. Temperature is appears. Temperature is too test strip for measurement. too high, outside the required low, outside the required range Action: Discard the test strip range of 10°C - 40°C (50°F - of 10°C - 40°C (50°F - 104°F).
  • Page 18 Manufacturer: EPS BIO TECHNOLOGY CORP. No.8, R&D RD. III, Hsinchu Science Park, Hsinchu, Taiwan 30077 TEL:+886-3-6686868 FAX:+886-3-6686866 E-mail:info@epsbio.com.tw Website:http://www.epsbio.com Obelis s.a. Boulevard Général Wahis 53, B-1030 Brussels, Belgium TEL:(32) 2.732.59 54 FAX:(32) 2.732.60 03 E-mail: mail@obelis.net P/N: 71800416B_0045B_02...