Electrical Adjustments
Group/
Item Name
Item
2 Fan1 Speed Gain
3 Fan2 Speed Gain
4 Fan3 Speed Gain
5 not used
Group 257 Fan Dimmer Setting
0 Dimmer Average Check Period
1 Dimmer Average
2 Last Voltage Difference
3 Voltate Difference Goal
Group 258 Fan IC Temp for Netowrk model
0 Standby Cooling Check Cycle
1 Standby Cooling Start Threshold
2 Standby Cooling Enable
Group 260 Auto Calibration (Commn) * Auto Calibration
0 Execute Calibration
1 Loop Count
2 Auto Status
3 AutoWait
4 CHECK -Tolelance
Group 261 Auto Calibration (RGB)
0 OFFSET AREA H START
1 OFFSET AREA V START
2 GAIN AREA H START
3 GAIN AREA V START
4 Image AREA H WIDTH
5 Image AREA V HIGHT
6 OFFSET target
7 OFFSET torelance
8 GAIN target
9 GAIN torelance
Group 262 Auto Calibration (CVBS/SVIDEO)
0 Y Image Area Start X
1 Y Image Area Start Y
6 Image Area H Width
7 Image Area V Hight
8 Y Target Level
11 Gain Tolerance
12 Delta Gain
Group 264 Auto Calibration (YCbCr)
0 Y-OFFSET AREA H START
1 Y-OFFSET AREA V START
2 CB - OFFSET AREA H START
3 CB - OFFSET AREA V START
4 CR - OFFSET AREA H START
5 CR - OFFSET AREA V START
6 Y - GAIN AREA H START
7 Y - GAIN AREA V START
8 CB - GAIN AREA H START
9 CB - GAIN AREA V START
10 CR - GAIN AREA H START
11 CR - GAIN AREA V START
12 Image AREA H WIDTH
13 Image AREA V HIGHT
14 Y - OFFSET TARTGET
15 CB OFFSET TARGET
16 CR OFFSET TARGET
17 Y - GAIN TARGET
18 CB - GAIN TARGET
19 CR - GAIN TARGET
20 OFFSET torelance
21 GAIN torelance
Group 280 AutoPC Adjsut
0 AutoPCAdjustEnable
1 Frequency Step
2 Frequency Threshold
Function
Additional Fan Speed of Min at Lamp Voltage
Down (unit: 0.1V)
Dimmer Avarage measurement Time
(0:10sec, 1:30sec, 2:6sec, 90sec...10:300sec)
Dimmer Avarage Value (Read only)
Temp A check cycle at Standby
Cooling start threshold temp A
Cooling in standby Ebable
Maximum Execution Times (OFFSET->GAIN)
Result of Auto-Calibration (Last Memory)
Wait Value for each setting
Torelance of OFFSET
Black Level Acquiring Area H-Start Position
Black Level Acquiring Area V-Start Position
White Level Acquiring Area H-Start Position
White Level Acquiring Area V-Start Position
Black/White Level Acquiring Area
Black/White Level Acquiring Area Height
Target Value of Black Level Adj.
Torelance of Black Level Adj.
Target Value of White Level Adj.
Torelance of White Level Adj.
Y Acquiring Area H-Start Position
Y Acquiring Area V-Start Position
Image Level Acquiring Area
Image Level Acquiring Area Height
Target Value of Y Level Adj.
Torelance of Level Adj.
Deviation Width of Gain Value
Y - Offset Acquiring Area H-Start Position
Y - Offset Acquiring Area V-Start Position
CB - Offset Acquiring Area H-Start Position
CB - Offset Acquiring Area V-Start Position
CR - Offset Acquiring Area H-Start Position
CR - Offset Acquiring Area V-Start Position
Y
YCBCR Level Acquiring Area
YCBCR Level Acquiring Area Height
Torelance of OFFSET Adj.
Torelance of GAIN Adj.
Auto-PC Adj Operation Enable if Un-
supported Signal Input
Frequency Steps of TotalDot
Total Dot Freqency Threshold
Initial
9999
1
-
-
0
10
0
1
2
975
500
25
500
13
9
3
1
238
1
20
500
13
20
217
1
9
925
500
925
500
925
500
50
500
800
500
700
500
8
9
4
128
128
217
237
237
1
1
0
1
5
-41-
Range
Note
0-255
0-255
0-255
0-255
0-10
Executes Auto-Calibration when changiing
0 - 1
the Value (PC White 100%)
1 - 30
0 / 1 / 9
0: OK, 1: Adjusting,9: Error * ReadOnly
1 - 20
1 - 255
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 127
1 - 127
0 - 255
1 - 255
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 255
0 - 255
0 - 255
0 - 1000
0 - 1000
0 - 1000
If not used: use Y's value
0 - 1000
If not used: use Y's value
0 - 1000
If not used: use Y's value
0 - 1000
If not used: use Y's value
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
1 - 255
1 - 255
0 - 1
0: Enable, 1: Disable
0-3
0 - 10
0 [] <--- -----> 10[Not matched]