B. Hearth Extension, Building and Fin-
ishing
WARNING! Risk of Fire! High temperatures, sparks,
embers or other burning material falling from the fire-
place may ignite flooring or concealed combustible
surfaces.
• Protective metal hearth strips MUST be installed.
• Hearth extensions MUST be installed exactly as
specified.
A hearth extension must be installed with all fire-
places to protect the combustible floor in front of the
fireplace from both radiant heat and sparks.
You MUST use a hearth extension with this
fireplace.
Refer to Figure 7.3 for minimum dimensions.
This fireplace has been tested and approved for use
with a hearth extension insulated to a minimum R
value of 1.03.
The hearth extension material MUST be covered
with tile, stone or other non-combustible material.
Manufactured hearth materials will usually have a
published R value (resistance to heat) or k value
(conductivity of heat). Refer to the formula in Table
7.1 to convert a k value to an R value,
Refer to Table 7.2 for hearth extension insulation
alternatives.
WARNING! Risk of Fire!
Vermont Castings Group is not responsible for
discoloration, cracking or other material failures of
finishing materials due to heat exposure or smoke.
• Choose finishing materials carefully.
VCG Sovereign Series • SA36R/SA42R • Installers Manual • 4010-259 • Rev A • 02/05/15
28
C
A
Hearth Extension Dimensions
Model #
in.
SA36
(HX3)
1321
mm
in.
SA42
(HX4)
mm
1676
Figure 7.3
Hearth Extension Dimensions
WARNING! Risk of Fire!
• Maintain clearances.
• Use only non-combustible material below standoffs, material
such as cement board is acceptable.
• Framing or finishing material used on the front of the fireplace
closer than the minimums listed, must be constructed entirely
of non-combustible materials (i.e., steel studs, concrete board,
etc.).
WARNING! Risk of Fire!
Hearth extensions are to be installed only as illustrated to prevent
high temperatures from occurring on concealed combustible
materials.
Table 7.1
R = 1/k x inches of thickness
Table 7.2
Hearth Extension Insulation Alternatives-Total minimum R
Value must equal 1.03
Material
HX3, HX4 (Micore 300™)
USG Micore 160™
USG Durock™ Cement Board
Cement Mortor
Common Brick
Ceramic Tile
Armstrong™ Privacy Guard
Plus
Marble
C
B
A
B
C
52
16
8
406
203
66
20
12
508
305
Minimum
k per inch
r per inch
thickness
thick
thick
required
0.49
2.06
1/2 in.
0.39
2.54
1/2 in.
1.92
0.52
5.0
0.20
5-1/8 in.
5.0
0.20
5-1/8 in.
12.50
0.08
12-1/4 in.
0.46
2.18
1/2 in.
14-5/8 in. - 20-3/8
14.3-20.0 0.07-0.05
2 in.
in.