ELECTRIC DRYER INSTALLATION REQUIREMENTS

Electrical Requirements
IMPORTANT: Observe all governing codes and ordinances.
This dryer is supplied without an electric cord and plug. It must be
connected by a competent electrician to a single-phase electricity
supply at the voltage shown on the dataplate, using a suitable
fixed wiring installation in accordance with local and national
wiring regulations.
■ A 3-wire circular cord of minimum conductor size 2.5 mm
cross-section area should be used.
■ A 25A (minimum) supply fuse should be used, and a switch
having a contact separation in both poles that provides full
disconnection under over-voltage category III conditions must
be incorporated into the fixed wiring in accordance with local
wiring regulations. The dryer should be positioned so that the
disconnection switch is clearly visible and easily accessible to
the user. This disconnection switch also provides the function
of an emergency stop control for the user.
■ A cord clamp bush is provided on the dryer, and should be
tightened on completion of wiring. The electrical mains terminals
are located behind the small rear access panel (terminal block
cover), and connections should be made in accordance with the
terminal markings. Remember to replace the terminal access
panel (terminal block cover).
NOTE: In accordance with the European EMC Directive
(2004/108/EC), the maximum electrical supply system impedance
to which the electric dryer should be connected is declared to be
0.054 Ohm + j0.034 Ohm.
NOTE: Electrical safety standards: The manufacturer has chosen
compliance with IEC/EN.60335 standards as the most appropriate
for this product.
10
This is 3-wire appliance which must be earthed.
2
If codes permit and an additional earth bond wire is used, it is
recommended that a qualified electrician determine that the earth
bond path is adequate.
Recommended Earthing Method
It is your responsibility to contact a qualified electrical installer
to ensure that the electrical installation is adequate and in
conformance with all local codes and ordinances.