Majestic fireplaces SC36A Homeowner's Installation And Operating Manual page 10

Sr/sc series "a" woodburning fireplace
Hide thumbs Also See for SC36A:
Table of Contents

Advertisement

SR/SC Series "A" Woodburning Fireplace
Straight-Up Chimney Installation
To mark the centerline of the flue, put the fireplace in
final position and measure out from the wall: 9 "
(235mm). Mark a spot on the ceiling directly above the
fireplace. Draw a line parallel to the back wall through
this mark. (Fig. 11)
Using a plumb bob positioned directly over center
point of fireplace flue collar, mark the ceiling to estab-
lish the chimney center point. (Fig. 11)
Offset Installation
In order to clear an obstruction, it may be necessary to
offset chimney from vertical. This is accomplished by
using CFM Corporation elbows. Use the 30 ° Offset
Elbow table on Page 6 to determine proper offset and
parts required.
Chimney Centerline
Actual Centerpoint
Fig. 11 Locate centerline of chimney with plumb line.
10
9 "
(235mm)
Plumb Line
Plumb Bob
Imaginary
Centerpoint
FP556
Each offset requires two (2) elbows. The second elbow
is equipped with support straps. It is very important to
install the second elbow in each offset as close to the
ceiling or support as possible so that the elbow straps
can be secured to framing members to help support
the weight of the chimney.
Determine offset distance of your chimney arrange-
ment from centerline of fireplace to centerline of
chimney where it is to pass through ceiling.
Locate center point of the chimney on ceiling as
though a straight up chimney arrangement is to be
used. Measure your offset dimension from straight up
chimney center point on ceiling.
Ceiling Chimney Hole/
Possible Obstructions
The size of the hole in ceiling will vary with the angle at
which the chimney passes through ceiling.
Drive a nail up through ceiling at marked chimney
center point. Go to floor above and see where hole will
be cut. Check to see where existing ceiling joists and
other possible obstructions are located...i.e. wiring,
plumbing etc... If necessary, reposition chimney and/or
fireplace to avoid obstructions.
Cutting the Hole
Cover fireplace collar opening and cut proper sized
chimney hole in chimney. The SK8 pipe allows you to
run pipe through a typical 16" on center joist without
cutting joists.
Framing the Ceiling Hole
Frame the ceiling chimney hole as shown in Figure 12.
It is good practice to use framing lumber that is the
same size as the ceiling joists; this is a requirement at
attic level.
Existing
AB
Ceiling Joist
Ceiling
New
Framing Members
A "SK" Series framing = 14 " X 14 " (368 x 368mm)
B "S" Series framing = 17 " X 17 " (445 x 445mm)
Fig. 12 Typical frame for ceiling chimney hole.
AB
Chimney Hole
FP551
7412948

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sc42aSr42aSr36aSr36aSr42aSc42a

Table of Contents