Mitsubishi Electric MUZ-FH25VEHZ Service Manual page 12

Outdoor unit
Hide thumbs Also See for MUZ-FH25VEHZ:
Table of Contents

Advertisement

MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFEFRENCE
Model
MUZ-FH25/35
MUZ-FH50
ADDITIONAL REFRIGERANT CHARGE (R410A: g)
Outdoor unit
Model
precharged
MUZ-FH25/35
1,150
Calculation: X g = 30 g/m × (Refrigerant piping length (m) - 7)
Outdoor unit
Model
precharged
MUZ-FH50
1,550
Calculation: X g = 20 g/m × (Refrigerant piping length (m) – 7)
OBH625A
Refrigerant piping: m
Max. Length A
Max. Height difference B
20
30
Indoor
unit
Max. Height
difference
B
Max. Length
7 m
8 m
0
30
7 m
10 m
0
12
15
A
Outdoor unit
Refrigerant piping length (one way)
9 m
10 m
11 m
60
90
120
Refrigerant piping length (one way)
15 m
60
160
12
Piping size O.D: mm
Gas
9.52
12.7
12 m
13 m
14 m
150
180
210
20 m
25 m
260
360
Liquid
6.35
6.35
15 m
20 m
240
390
30 m
460

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Muz-fh35vehzMuz-fh50vehz

Table of Contents