OPERATING PROCEDURE
5. Removing the outdoor fan motor
(1) Remove the service panel, the top panel and the cabinet
(Refer to 1).
(2) Disconnect the power supply and indoor/outdoor
connecting wire.
(3) Disconnect the connectors for outdoor fan motor.
(4) Remove the propeller fan nut.
(5) Remove the propeller fan.
(6) Remove the screws fixing the fan motor.
(7) Remove the fan motor.
6. Removing the compressor and the 4-way valve
(1) Remove the service panel, the top panel and the cabinet
(Refer to 1).
(2) Disconnect the power supply and indoor/outdoor
connecting wire and remove the back panel (Refer to 1).
(3) Remove the inverter assembly (Refer to 2).
(4) Recover gas from the refrigerant circuit.
Recover gas from the pipes until the pressure gauge
NOTE:
shows 0 kg/cm
(5) Detach the brazed part of the suction and the discharge pipe
connected with compressor.
(6) Remove the nuts of compressor legs.
(7) Remove the compressor.
(8) Detach the brazed part of pipes connected with 4-way valve.
Photo 10
Compressor nuts
OBH626F
(0 MPa).
2
Discharge pipe brazed part
Suction pipe brazed part
Photo 7
Outdoor heat
exchanger
temperature
thermistor (RT68)
Photo 8
Screws of the fan motor
Propeller fan
Photo 9
Brazed parts of 4-way valve
123
PHOTOS
Defrost
thermistor
(RT61)
Base heater
(MXZ-2D53VAH only)
Propeller fan nut