IL603 Section B Rev. 5- 09/2001 ® Tek-SELECT SM400 Series Multi-Master and Master/Remote Intercom Systems Operation, Installation and Service Manual Website: www.tektone.net Email: tektone@tektone.net For Technical Assistance: 1-800-332-6608 Technical Assistance Email: teksupt@tektone.net 277 Industrial Park Road Franklin, NC 28734 (828) 524-9967...
Page 2
Signal Mfg., Inc. assumes no responsibility or liability for any errors or inaccuracies that may appear in this documentation. TekTone, the TekTone logo, Tek-Call, Tek-Care, Tek-Check-In, Tek-Com, Tek-Digicare, Tek-Door, Tek-Entry III, Tek-Guard, Tek-Micro, Tek-MMARS II, Tek-NIOS, Tek-Paging, Tek-Phone, Tek-Safe, Tek-Select II, Tek-Sentry, Tek-Sound, Tek-Status and Tek-View are either registered trademarks or trademarks of TekTone ®...
TABLE OF CONTENTS 1.0 SYSTEM INSTALLATION Installation Procedure ..............1 Planning and Equipment Location ........... 1 Masters and Remotes .............. 1 Power Supply and Relays ............1 Transformer ................1 Music System ................1 System Housings ................1 Wiring Installation ................1 Master Stations .................
(power supply) location. ® NOTE: TekTone is not responsible for interference resulting If all call relay is not used, limit length of cable as follows: from improper installation.
Section 1.0 — SYSTEM INSTALLATION Background Music: 1.6 Equipment Installation Add 1 wire to master-to-master cable. Surface Mounting SM404, SM406 and SM411 Masters: Run 2 wires #18 twisted from music system to central 1. Install IH401 cabinet on wall. Cabinet may be installed equipment location, 100 feet (30 meters) maximum.
Section 1.0 — SYSTEM INSTALLATION These switches may be set as needed; however, note the fol- Blue (D): This line activates the door release on the PK400 lowing points: power supply, and is also used when the RY400 remote control relay is installed. 1.
Section 2.0 — OPERATING INSTRUCTIONS 2.1 Master Station Open the door (if installed): 1. Press the button (identified by a key). DOOR Call another station: Page all stations (if installed): 1. If the light is not illuminated red, select the desired TALK station by pressing its associated selector button.
Figure 8 — SM406 Master to Master Wiring Diagram Figure 9 — SM406 Master to Remote Wiring Diagram SS106 PK400 T R A N S F O R M E R P O W E R S U P P L Y SS106 24 V.A.C.
Figure 10 — SM406/RY400 Wiring Diagram Figure 11 — SM406/RY402 Wiring Diagram SS106 PK400 N O T E S : TRANSFORMER POWER SUPPLY 1. Actual terminal locations not shown. See terminal identification diagrams. 2. Connect power transformers to 115 V.A.C. in accord with local electrical codes. 3.
Figure 12 — SM401 Wiring Diagram Figure 13 — RY401 and RY402 application with SM404 Master NOTES: 1. Actual terminal locations not shown. See terminal identification diagrams. 2. Connect power transformers to 115 V.A.C. in accord with local electrical codes. S S 1 0 6 P K 4 0 0 T R A N S F O R M E R...