INSTALLATION AND

OPERATING INSTRUCTIONS

LUX PRODUCTS CORPORATION
Mt. Laurel, New Jersey 08054, USA
www.luxproducts.com
T40-1143SA
HEATING & COOLING
THERMOSTAT
ATTENTION : not for use with
compressors without time delays.

SPECIFICATIONS

ELECTRICAL RATING
24 Vac (30 Vac Maximum)
SWITCH ACTION
Open contact switch
ANTICIPATOR RATING
(HEATING) 0.15A to 1.2A
(COOLING) Fixed 24 VAC
TEMPERATURE RANGE
50°F to 90°F
INSTALLATION & OPERATION
1). THERMOSTAT LOCATION
For accurate temperature control and comfort, correct location is very important. On
new installations, the guidelines listed below should be followed as closely as
possible. When replacing an old thermostat, install the new one in the same location
unless these conditions suggest otherwise.
1. Locate the thermostat on an inside wall about five feet above the floor, where it is
easy to install and adjust. It should be in a room that is used often, such as a family
room.
2. Do not install it where there are unusual heating conditions, such as direct sunlight,
close to a lamp, radio, television, radiator, register, near a fireplace, or other heat
producing appliance. Also, check for hot water pipes within the wall, or a stove on
the other side of the wall.
3. Do not locate in unusual cooling conditions, such as on an outside wall, or one
separating an unheated room, or in drafts from stairwells, doors, or windows.
4. Do not locate in a damp or humid area. This can shorten thermostat life due to
corrosion.
5. Do not locate where air circulation is poor, such as in a corner, alcove, or behind an
open door.
6. Do not install until all construction work and painting have been completed.
2) TOOLS REQUIRED
3
Wirestripper or knife, drill with
" bit, screwdriver, level and a pencil.
16
50
60
70 80 90
10
15
20
25 30
LUX
LUX
20
25
15
70
30
60
80
10
50
90
© COPYRIGHT 2006 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
3) REMOVING OLD THERMOSTAT
Please read all instructions carefully. As you complete each step, check the
adjoining square
■ ■
Disconnect electricity and turn off gas to the heater.
■ ■
Remove cover from old thermostat.
■ ■
Disconnect wires from thermostat, making sure they do not fall back inside the wall.
Make note of wires and to which terminals they are attached as you disconnect
52022
them. For example: "Yellow wire to terminal Y, Red wire to terminal RH," etc.
■ ■
3
Strip insulation
■ ■
Loosen all screws on the old thermostat and remove it from the wall.
■ ■
Fill wall opening with non-combustible insulation to prevent drafts from affecting
thermostat.
4) INSTALLING NEW THERMOSTAT
■ ■
Place new decorative wall plate (if supplied), Figure 4, over wall opening.
Decorative wall plate can optionally be left off.
■ ■
Remove Front Cover of new thermostat by inserting a finger in the side of the
thermostat and gently prying away each corner. Remove Base, Figure 2, from
Sub-Base, Figure 3, by loosening three captive screws.
■ ■
Place Sub-Base, Figure 3, on wallplate over wall opening. Mark wall with pencil at
mounting holes as shown in Figure 2. Now lay wallplate and Sub-Base to the side.
■ ■
Drill two holes with
■ ■
Insert plastic screw anchors into drilled holes, flush with wall surface.
■ ■
Bring wires through large hole in decorative wall plate and through Hole For
Wires in Sub-Base.
■ ■
Referring to your notes and the following diagrams, attach wires to terminal
screws shown in Figure 2. Make sure bare metal wires do not touch each other.
Push all excess wire back into wall.

WIRING DIAGRAMS

FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
HEATING TRANSFORMER
DAMPER OR CHANGEOVER VALVE
G
Y
W RH B
Tape Off **
Tape Off
* If replacing a Honeywell TM-11,
tape off wire "R"; connect wire "B"
to terminal "RH."
** If replacing a Honeywell thermostat
with a clock wire "C," tape off wire "C"
Heating/Cooling Systems
4- or 5-Wire with One Transformer
FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
HEATING TRANSFORMER
DAMPER OR CHANGEOVER VALVE
G
Y
W RH B
Tape Off
*
* If both Y and C wire are
present, tape off "C" wire.
■ ■
✓.
" from wire ends and clean off any corrosion.
8
3
" bit, 1" deep.
16
Heating Systems
FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
(POWERED IN HEAT)
DAMPER OR CHANGEOVER VALVE
(POWERED IN COOL)
COOL TRANSFORMER
O RC
G
Y
Tape Off *
* If both Y and C wire are
present, tape off "C" wire.
FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
(POWERED IN HEAT)
DAMPER OR CHANGEOVER VALVE
(POWERED IN COOL)
COOL TRANSFORMER
O RC
G
Y
Tape Off
(Optional)
(Optional)
* If both Y and C wire are
present, tape off "C" wire.
Cooling Systems
HEATING TRANSFORMER
DAMPER OR CHANGEOVER VALVE
(POWERED IN HEAT)
DAMPER OR CHANGEOVER VALVE
(POWERED IN COOL)
COOL TRANSFORMER
W RH B
O RC
Tape Off
*
Heating/Cooling Systems
5- or 6-Wire with Two Transformers
HEATING TRANSFORMER
DAMPER OR CHANGEOVER VALVE
(POWERED IN HEAT)
DAMPER OR CHANGEOVER VALVE
(POWERED IN COOL)
COOL TRANSFORMER
W RH B
O RC
*
(Optional)
(Optional)

Advertisement

loading

Summary of Contents for Lux Products T40-1143SA

  • Page 1: Operating Instructions

    1. Locate the thermostat on an inside wall about five feet above the floor, where it is easy to install and adjust. It should be in a room that is used often, such as a family room.
  • Page 2: Technical Assistance

    WARRANTY Limited Warranty: If this unit fails because of defects in materials or workmanship within three years of date of original purchase, LUX Products Corporation will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions.