Immediately before handling any semiconductor components or assemblies, drain the electrostatic charge from your SAMSUNG ELECTRONICS AMERICA, INC. body by touching a known earth ground. HEADQUARTER OFFICE 105 CHALLENGER ROAD 16. Always connect a test instrument's ground RIDGEFIELD PARK N.J.07660-0511...
(Use a screwdriver.) 3. High voltage is maintained within specified limits by close-tolerance, safety-related components and adjustments. If the high voltage exceeds the specified limits, check each of the special components. Fig. 1-1. Discharging the High Voltage Capacitor Samsung Electronics...
4-2 Replacement of High Voltage Transformer 1. Discharge the high voltage capacitor. 2. Disconnect all the leads. 3. Remove the mounting bolts. 4. Reconnect the leads correctly and firmly. Bolts H. V. Trans Samsung Electronics...
1. Insertion depth of the thin metal plate should be 0.5mm or less. 4-3-4 Removal of Key Door & Spring Remove pin hinge from Door "E" Door "E" Detach spring from Door "E" and key door. Key Door Spring Samsung Electronics...
3. Do the microwave leakage test. 4-4 Replacement of Fuse 1. Disconnect the oven from the power source. 2. Remove the 15A(MR5481G / MR5482W) / 20A(MR6481G / MR6482W) fuse in the fuse holder. 3. When replacing the fuse, be sure to use an exact replacement part.
Page 9
3. When installing new membrane key board, make sure that the surface of escutcheon base is Membrane cleaned sufficiently so that any problems Panel (shorted contacts or uneven surface) can be avoided. Samsung Electronics...
2. Isolate the magnetron from the circuit by disconnecting its leads. 3. A continuity check across the magnetron filament terminals should indicate one ohm or less. 4. A continuity check between each filament terminal and magnetron case should read open. Cooling Fins Samsung Electronics...
∞ procedures. Primary switch ∞ Secondary switch 5. Confirm that the gap between the switch ∞ Monitor switch (COM-NC) housing and the switch actuator is no more than ∞ Door Sensing S/W 0.5mm when door is closed. Samsung Electronics...
Page 12
5. After heating for 2 minutes, measure the water temperature in each beaker. 6. Microwave heat distribution rate can be calculated as follows: Minimum Beaker Temperature Rise Heat Distribution = X 100(%) Maximum Temperature Rise The result should exceed 65%. Cooking Tray Samsung Electronics...
2) If the radiation leakage is more than 5 mW/§† after determining that all parts are in good condition, functioning properly and the identical parts are replaced as listed in this manual notift that fact to ; SAMSUNG ELECTRONICS AMERICA, INC. HEADQUARTER OFFICE 105 CHALLENGER ROAD RIDGEFIELD PARK N.J.07660-0511...
H.V.Transformer component test procedure and replace if it is H.V.Capacitor defective. H.V.Diode Magnetron 4. Open or loose wiring of power relay 5. Defective primary latch switch 6. Defective power relay or Ass'y PCB Replace PCB main. Samsung Electronics...
Page 15
Use plastic wrap or cover with a lid. Stir once or twice while cooking foods such as soup, cocoa, or milk. Noise from the turntable motor Noise may result from the motor. Replace turntable motor. when it starts to operate. Samsung Electronics...
ORG : ORANGE : P.C.B IN/OUT POINT BLK BLU : GREEN (CON1) DOOR PRIMARY INTERLOCK SENSING INTERLOCK MONITOR SWITCH SWITCH SWITCH MAGNETRON HIGH VOLTAGE DIODE TO CHASSIS HIGH VOLTAGE CAPACITOR SYMBOL COLOR ORANGE HIGH VOLTAGE WHITE TRANSFORMER BLACK BLUE Samsung Electronics...