  • Page 1 INSTRUCTION MANUAL REVO ELITE 36x IR SPEED DOME CAMERA Model#: RESPTZ36-3...
  • Page 2 Please read this manual thoroughly before use and keep it handy for future reference.
  • Page 3: Explanation Of Graphical Symbols

    WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR OTHER OPENINGS ON THE EQUIPMENT. CAUTION EXPLANATION OF GRAPHICAL SYMBOLS The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage”...
  • Page 4: Fcc Compliance Statement

    FCC COMPLIANCE STATEMENT FCC INFORMATION: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 5: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with dry cloth. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  • Page 6: Table Of Contents

    Table of Contents Chapter 1 — Introduction ..................... 1 1.1 Features ............................. 1 Chapter 2 — Installation and Configuration ..............2 2.1 Package Contents ........................2 2.2 Installation ..........................2 2.1.1 Installation - Wall Mount ....................3 2.1.2 Installation - Ceiling Mount ..................... 4 2.3 Basic Configuration of Camera System ................
  • Page 7: Chapter 1 - Introduction

    Chapter 1 — Introduction 1.1 Features The dome camera and the keyboard controller make up the building blocks for any surveillance/security system. Using multiple Keyboard Controllers and multiple dome cameras, no place is too large for monitoring. Extensible and flexible architecture facilitates remote control functions for a variety of external switching devices such as multiplexers and DVRs.
  • Page 8: Chapter 2 - Installation And Configuration

    Chapter 2 — Installation and Configuration 2.1 Package Contents The package contains the following. Dome Camera Instruction Manual (This Document) 2P screw type Connector 5P screw type Connector 12VDC Adaptor 2.2 Installation You need one optional mount kit of the wall mount and the ceiling mount to install. The wall or ceiling mount must be attached to a structural object such as hard wood, concrete that will support the weight of the mount and dome camera.
  • Page 9: Installation - Wall Mount

    2.1.1 Installation - Wall Mount The wall mounting plate must be attached to a structural object such as concrete that will support the weight of the mount and Dome Camera. 1. Select a suitable mounting location and verify there is sufficient cable to reach the middle of the Wall Mount.
  • Page 10: Installation - Ceiling Mount

    2.1.2 Installation - Ceiling Mount The ceiling mounting plate must be attached to a structural object such as concrete that will support the weight of the mount and Dome Camera. 1. Select a suitable mounting location and verify there is sufficient cable to connect with cables from the housing.
  • Page 11: Basic Configuration Of Camera System

    2.3 Basic Configuration of Camera System CONNECTOR COLOR DESCRIPTION DC JACK BLACK 12VDC BNC Cable BLACK VIDEO OUTPUT ALARM INPUT 1 ORANGE/WHITE ALARM INPUT 2 5P Cable ORANGE ALARM INPUT 3 GREEN/WHITE ALARM INPUT 4 BLACK BLUE ALARM OUTPUT GRAY 5P Cable GREEN COM (RELAY)
  • Page 12: Setting Dome Camera Address (Id)

    2.4 Setting Dome Camera Address (ID) When the COMMUNICATION MODE is set to S/W Dome camera address (ID) and Protocol can be used by selecting from the MENU. You can call up the On-screen menu utility on your monitor by pressing MENU key on the keyboard controller, the following On-screen menu utility will appear: DOME MENU AUTO SCAN...
  • Page 13 When the COMMUNICATION MODE is set to H/W Dome camera address (ID) and Protocol can be used by selecting from the Hardware. To prevent damage, each dome camera must have a unique address (ID). When installing multiple dome cameras using a multiplexer, it is suggested that the dome camera address match the multiplexer port number.
  • Page 14: Setting Dome Camera Protocol

    2.5 Setting Dome Camera Protocol If a dome camera is to be installed with a Fastrax keyboard controller, select the default protocol. Consult service personnel if a dome camera is installed with device other than a keyboard controller. UNCTION NTSC S4-1 Enable Disable...
  • Page 15: Connections Setting Dome Camera Termination

    2.6 Connections Setting Dome Camera Termination The device which is connected at end of line, whether it be a dome camera or keyboard controller, must have the cable for communication terminated by setting the appropriate DIP switch. Without proper termination, there is potential for control signal errors. Total length of the cable for communication should not exceed 4000ft (1.2km).
  • Page 16: Connections

    2.7 Connections • Connecting to the RS485 The dome camera can be controlled remotely by an external device or control system, such as a control keyboard, using RS485 half-duplex. Connect Marked RS_485+(A), RS_485-(B) of the RS485 control system. • Connecting Video output connector Connect the video output (BNC) connector to the monitor or video input.
  • Page 17: Getting Started

    2.8 Getting Started Once installed apply power to the dome camera. The dome camera will start a configuration sequence. PRESET TITLE AREA TITLE STATUS of AF AE FUNCTION FOCUS and AE UNDER RUNNING CAMERA TITLE EMPTY DATA INFORMATION DISPLAY CAMERA ID DOMEID:0001 ALARM:1 W→360.0,090.0...
  • Page 18: Chapter 3 - Program And Operation

    Chapter 3 — Program and Operation 3.1 Dome Camera Selection Before you program or operate a dome camera, you must select the dome camera by pressing the dome camera No. + CAM Example: Pressing 1 , 0 and CAM key sequentially will select dome camera 10. The selected dome camera ID will be displayed on the LCD monitor of the keyboard controller.
  • Page 19: Auto Scan (Shortcut: Scan)

    3.4 Auto Scan (Shortcut: SCAN) The Auto scan supports up to 17 programmed angles at user-programmable speeds. Follow these steps to program Auto Scan: AUTO SCAN SETUP NUMBER : 01 TITLE : A01 MODE : NORMAL SPEED 5 STEP START ANGLE : ----- ----- END ANGLE : ----- ----- SCAN DIR...
  • Page 20 5. Select “MODE” and “SPEED”. 6. Select “START ANGLE”. Hold down the CTRL key while selecting the start position using the Joystick. Current panning position will be displayed. Release CTRL key to complete the selection of the start position. Or Press IRIS Open then the “CTRL” displays. Move the desired position and the zoom position.
  • Page 21: Preset (Shortcut: Prst)

    3.5 Preset (Shortcut: PRST) If you need to view specific places routinely, you should program presets. A preset is a programmed video scene with automatic pan, tilt, zoom, focus, and AE settings. Once programmed, placing the number position and pressing a PRST button on your controller calls up that preset automatically. In addition, presets may be assigned to alarm actions or as the “home”...
  • Page 22 MOTION SETUP SENSITIVITY : 6 POSITION : ALL DELAY : 00 SEC OUTPUT : OFF HOLD TIME : 03 SEC EXIT(ESC TO EXIT) Set SENSITIVITY: 1~10 Set POSITION: ALL, CENTER Set DELAY: 0~5 SEC Set OUTPUT: OFF,OUT, RELAY Set HOLD TIME: 3~99 SEC Select “AE SETUP”...
  • Page 23: Shortcut Of Preset Program

    3.6 Shortcut of Preset Program After selecting the desired scene, press No. (1 to 240), and press CTRL and PRST subsequently. The current view will be stored to the selected preset number if the preset number is empty. If selected preset number is not empty, “OVER WRITE”...
  • Page 24: Pattern (Shortcut: Ptrn)

    7. Repeat Step 2 through 5 for each desired position. Each title will be displayed on top of the line. 8. To edit the title, follow the procedure of the auto scan above to edit titles 9. Select Save and Exit and push the Joystick to the right. Press ESC to exit the program without saving.
  • Page 25: Alarm

    3. Press and hold down the CTRL key while controlling the camera direction and zoom with the Joystick. The dome will be automatically recorded until you release the CTRL key. Or Press IRIS Open then the “CTRL” displays. Move the position and the zoom position. Press IRIS Close then the “CTRL”...
  • Page 26: Area Title

    The ALARM OUT setup is helpful when the outdoor housing is used with the dome. Ex.) When you connect the relay output of the dome to the heater connector of the outdoor housing, the relay output can operate during the setting time only. ALARM OUT SETUP : ALARM RELAY...
  • Page 27: Privacy Zone

    2. To edit the title, follow the procedure of the auto scan above to edit titles. 3. Select “START ANGLE”. Hold down the CTRL key while selecting the start position using the Joystick. Current panning position will be displayed. Release CTRL key to complete the selection of the start position.
  • Page 28: Camera Menu

    PRIVACY AREA MENU (CTRL KEY) CONTROL NUMBER 001 354.8 344.8 3. Place the cursor at the title field. Twist the Joystick to enter the title edit mode. Follow the procedure of the auto scan above to edit titles. 4. To turn the stored zone On or Off, twist the Joystick handle or press Tele or Wide Key. 5.
  • Page 29 • FOCUS CONTROL FOCUS SETUP MODE : AUTO FOCUS LIMIT : 0.5M SAVE AND EXIT(ESC TO CANCEL) MODE AUTO / MANUAL / ONE PUSH / CONSTANT MANUAL Use manual mode in normal use. FOCUS LIMIT This distance is approximate value and the focus operate from the setting value. CAUTION: Avoid continuous, 24-hour use of the auto focus.
  • Page 30 Auto exposure mode1.(Use to normal surroundings : indoor) Auto exposure mode2 (Use to high brightness surroundings : outdoor) SHUTTER PRIO Variable Shutter speed, Auto Gain. MANUAL Variable Shutter speed, Gain. DSS LIMIT OFF / x2 / x4 / x8 / x16 / x32 / x64 / x128 / x256 / x512 GAIN MIN / LOW / MID / HIGH BRIGHT...
  • Page 31 • IR CONTROL When used with IR illuminator, changing the zoom ratio automatically synchronizes the IR illuminator. IR CONTROL IR MODE : SENSOR FIXED IR BRIGHT MOVING IR BRIGHT IR ON LEVEL : 035 IR OFF LEVEL : 05 IR DELAY : 03 FIXED IR LEVEL : 48...
  • Page 32 CAMERA CONTROL SETUP SHARPNESS : 07 IR SHARPNESS : 15 RESOLUTION : LOW DIGITAL ZOOM : OFF IMAGE FLIP : OFF PRESET FREEZE : OFF STABILIZATION : OFF SAVE AND EXIT(ESC TO CANCEL) SHARPNESS The higher the value, the more edges in the picture will be enhanced.
  • Page 33: Dome Setup

    3.13 Dome Setup CONFIGURATION MENU LANGUAGE : ENGLISH HOME FUNCTION SETUP OSD DISPLAY VIEW ANGLE SETUP INITIALIZE DATA DOME RESET SYSTEM MENU SYSTEM INFORMATION SAVE AND EXIT(ESC TO CANCEL) • LANGUAGE SETUP LANGUAGE : Select the language you want. • HOME FUNCTION SETUP HOME FUNCTION SETUP HOME FUNCTION : NONE...
  • Page 34 • OSD DISPLAY OSD DISPLAY SETUP CAMERA TITLE : DOMEID VIEW DIRECTION : OFF DOME OSD : ON AREA TITLE : OFF PRESET TITLE : CONSTANT FOCUS EXPOSURE : ON OSD POSITION SETUP SAVE AND EXIT(ESC TO CANCEL) CAMERA TITLE : up to 6 characters.
  • Page 35 • VIEW ANGLE SETUP VIEW ANGLE SETUP PANNING RANGE FLIP : ON TILT ANGLE LIMIT : 00° SAVE AND EXIT(ESC TO CANCEL) FLIP ON / OFF the dome camera moves until 90° vertically. When the camera reaches the floor directly above the moving object, it will stop. At that time, release the Joystick handle instantly and pull it down again to run the auto-flip function.
  • Page 36 • INITIALIZE DATA INITIALIZE DATA FACTORY DEFAULT ERASE PROGRAMMED DATA PRESET FOCUS DEFAULT EXIT (ESC TO CANCEL) FACTORY DEFAULT Select the Factory Default to initialize the Data. FACTORY DEFAULT ARE YOU SURE ? CANCEL ERASE PROGRAMMED DATA Erase all stored data from the Flash-ROM of the selected dome camera. You will be asked to enter ON or OFF.
  • Page 37 PRESET FOCUS DEFAULT This menu set the default mode of the focus when you save the preset. PRESET FOCUS DEFAULT FOCUS : AUTO SAVE AND EXIT(ESC TO CANCEL) FOCUS : AUTO/MANUAL/ONE PUSH • DOME RESET DOME RESET ARE YOU SURE ? CANCEL This feature is used to re-calibrate the orientation of a selected dome camera.
  • Page 38 MOTOR SETUP Motor Setup menu provides the pan and tilt speed of a camera. User can set the desired speed with twist the Joystick left or right. During operation, pressing 153 + ON will change the speed to the SLOW mode and pressing 153 + OFF will change the speed to the Normal mode.
  • Page 39: Dome Communication

    WHITE DEFECT COMPENSATION wWhite defect of CCD sensor will be compensated. WHITE DEFECT COMPENSATION ARE YOU SURE ? CANCEL • SYSTEM INFORMATION SYSTEM INFORMATION CAMERA TYPE : xxxx H/W VERSION : Vx.xx ROM VERSION : Vx.xx PROTOCOL : xxxx BUADRATE : 9600 IR VERSION : x.xx EXIT(ESC TO EXIT)
  • Page 40: Function Run

    3.15 Function Run This Function Run menu allows you to execute the function when you use a keyboard or a DVR without the function keys (Preset, Pattern, Tour and scan). FUNCTION RUN SETUP (CTRL KEY) PRESET : --- PATTERN : --- TOUR : --- SCAN...
  • Page 41: Motion Setup

    3.16 Motion Setup The motion detection function is available in the preset mode only. After you set the motion in any preset, when you call the preset with the motion, the motion detection operates. In the preset setup, you can set the motion setup as below. PRESET SETUP PRESET CAMERA SETUP NUMBER...
  • Page 42: Appendix A - Specifications

    Appendix A — Specifications 36x FASTRAX V IR SPEED DOME CAMERA MODEL MODULE CCD Type 1/4" Super HAD CCD II (Double Scan) Optical / Digital Zoom 36X / 16X Resolution (NTSC/PAL) 700 TVL Focal length f = 3.4mm ~ 122.4mm 3.4mm –...
  • Page 43 Electrical Input Voltage 12VDC Power Consumption 1 TTL output, Alarm Output 1 Relay output 24VDC/1A Max. (selectable NC/NO) Alarm Input 4 Normal dry contact (selectable NC/NO) RS-485 baud rate: 2400~38.4k bps Control (default: 9600bps) ID (Camera Address) 999 (3999 by software setting) Built-in IR Synchronized IR LED &...
  • Page 44: Appendix B - Troubleshooting

    Appendix B — Troubleshooting If problems occur, verify the installation of the camera with the instructions in this manual and with other operating equipment. Isolate the problem to the specific piece of equipment in the system and refer to the equipment manual for further information.
  • Page 45: Appendix C - Glossary

    Appendix C — Glossary ALARM ACTIONS The assigned responses for the dome camera when inputs change from normal to abnormal states. The dome may run a Preset, Pattern, or have no assigned action for each of the four dome inputs. The dome may also send alarm states to the host controller for processing.
  • Page 46: Slow Shutter

    NORMAL INPUT STATE Describes the expected state of a device connected to one of eight dome camera’s inputs. The normal state may be open or closed. When a device is not in its normal input state, an alarm is issued. NORTH POSITION User-definable setting that may correspond to magnetic north or some well-known landmark.
  • Page 47: Appendix D - Short Cut Key

    Appendix D — Short Cut Key Short Cut Key Function PRST Pop up preset setup menu. TOUR Pop up Tour setup menu. PTRN Pop up Pattern setup menu. SCAN Pop up Auto Scan setup menu. NO.+ CTRL +PRST Store the current view at the selected number. Short Cut Key Function Short Cut Key...
  • Page 49 REVO ELITE 36x IR SPEED DOME CAMERA Printed in Korea 50303587B...

Table of Contents