POWER c QNNEcvoN(conti
flu@q
230/208 Volt
Wal! Plug
Heater Wattage
Line Cord Kits
Configuration
CircuitProtectiveDevice
@230/208 Volts
RAK315
Tandem
15 Amp TD Fuseor Breaker
2.55/2.09 i<vv
FiAK320
Perpendicular
20 Amp TK)fuse or Breaker
3.45/2.82 KW
RAI<330*
LargeTandem
30 Amp Fuseor Breaker
5.00/4.10 KW
230/208
Voit
Permanent
Heater Wattage
Connection Kits
CircuitProtectiveDevice
@230/208 Volts
RAK415/415L
15 Amp TD Fuseor Breaker
2.55/2.09 KW
RAK420/420L
20 Amp TD Fuseor Breaker
3.45/2.82
I<W
RAK430/430L*
30 Amp TD Fuseor Breaker
5.00/4.10 I<w
Kitsending in "L have flexible conduit to reachfrom the kitto the knockouthole (above right sideinspection
plate) in the RAI<203 Sub-Base.
265 Volt
Permanent
Heater Wattage
Connection Kits
CircuitProtective Device
@265 Volts
RAK515/515LF
15 Amp TD Fuse
1.70 KW
RAK517/517LF
15 Amp TD Fuse
3.00 KW
RAK520/520LF
20 Amp TD Fuse
3.70 KW
RAK530/530LF*
30 Amp TD Fuse
5.00 KW
I<itsending in "LF"
have flexible conduit to reach from the kit to the knockout hole (above right
side inspection
plate) in the RAK203 Sub-Baseand have an Integral Fuse.
*f~ot recommended for use on 6000 BTUH Units.(If this connection kit is used it will providea maximum
heat of 3.45 I<W at 230 volts and 3.7 I<W at 265 volts.)
The discharge air louverscan be adjusted
with the fingers to different positionsranging
from approximately 15° off vertical to
approximately 60° off vertical.
Air Discharge Louvers