Electricalrequirements; Grounding - GE Zoneline Heat Pump 5100 series Use And Care Manual

Table of Contents

Advertisement

Read these instructionscompletely and carefully.
lMPORTANT—Observe all governing codes and
ordinances.
lNSTALLEH—Besure to leave these
instructions with the Consumer.
CONSUMER—!(eep these instructions for
future reference.
FOR PERSONAL SAFETY
@ Follow National Electrical Code (NEC) and
local codes, ordinances and regulations. All
wiring — including installation of receptacle,
must be in accordance with these codes.
This unit must be properly grounded.
Do not use an extension cord with this unit.
NEC requires permanent connection for
installations over 250 volts.
NEC requires units controlled by NEC Class
2 low voltage remote controls to be
permanently connected.
Protective
devices (fusesor circuit breakers)
acceptable for Zoneline installationsare
specified on the nameplate of each unit.
Aluminum building wiring may pose special
problems--consult a qualified electrician.
Disconnect power to the air conditioner before
servicing by:
1. Removing the power cord from the wall
receptacle, if it has one.
2. Retnoving the branch circuit fuses or turning
the circuit breakersoff at the panel.
Before
statiirag the
installation. the power to
the direct connect wiring should be OFF.
"
THE
GEZONELINP
ExteriorGrille/Louver**
RoomCabinet*
n
*
Shipped with the chassis
** Check essential elements list on chassis
*** Line cord connection shown only as example
WALL CASE & GRILLE
~. The RAB 70 or 77 Wall Case must be
properly installed per instructionspacked
with the case.
2. Remove the corrugated stiffener and the
outdoor protective panel. Use the slit in the
outdoor panel as a handhold and push out.
Protective
Panel
Slit
Stiffener
3.
Install the Exterior Grille from the room side
per instruction packed with the grille.
—.
....
— ..———-———.-----=