Available languages

The unit stops and the TIMER indicator blinks.
Use remote control to retrieve error code.
1
Press for 5 seconds
3 Press for 5 seconds
to quit checking
• For certain errors, you may restart the unit for limited operation with 4 beeps when operation starts.
Diagnostic
Abnormality/Protection
display
control
H 00
No memory of failure
Indoor/outdoor abnormal
H 11
communication
H 12
Indoor unit capacity unmatched
Indoor intake air temperature
H 14
sensor abnormality
Compressor temperature sensor
H 15
abnormality
Outdoor current transformer (CT)
H 16
abnormality
H 19
Indoor fan motor mechanism lock
Indoor heat exchanger
H 23
temperature sensor 1 abnormality
Indoor heat exchanger
H 24
temperature sensor 2 abnormality
H 25
Indoor ion device abnormality
Outdoor air temperature sensor
H 27
abnormality
Outdoor heat exchanger
H 28
temperature sensor 1 abnormality
Outdoor discharge pipe
H 30
temperature sensor abnormality
Outdoor heat exchanger
H 32
temperature sensor 2 abnormality
Indoor/outdoor misconnection
H 33
abnormality
Outdoor heat sink temperature
H 34
sensor abnormality
Outdoor gas pipe temperature
H 36
sensor abnormality
Outdoor liquid pipe temperature
H 37
sensor abnormality
Indoor/outdoor mismatch
H 38
(brand code)
2
Press until you hear beep sound, then
TIMER
TIMER
ON
ON
SET
SET
write down the error code
1
1
2
3
3
OFF
OFF
CANCEL
CANCEL
4
Turn the unit off and reveal the error code
AC
AC
RC
RC
to authorised dealer
SET CHECK CLOCK
SET
CLOCK
RESET
RESET
Diagnostic
display
Abnormality/Protection
control
Abnormal indoor operating unit or
H 39
standby units
Abnormal wiring or piping
H 41
connection
H 59
Eco sensor abnormality
Outdoor high pressure sensor
H 64
abnormality
H 70
Light sensor abnormality
Outdoor fan motor mechanism
H 97
lock
H 98
Indoor high pressure protection
Indoor operating unit freeze
H 99
protection
4-way valve switching
F 11
abnormality
Indoor standby units freezing
F 17
abnormality
Power factor correction (PFC)
F 90
circuit protection
F 91
Refrigeration cycle abnormality
F 93
Compressor abnormal revolution
Compressor discharge pressure
F 94
overshoot protection
Outdoor cooling high pressure
F 95
protection
Power transistor module
F 96
overheating protection
Compressor overheating
F 97
protection
F 98
Total running current protection
Outdoor direct current (DC) peak
F 99
detection