Premier AA-1821 Instruction Manual

Premier AA-1821 Instruction Manual

Split type room air conditioner

Advertisement

Quick Links

AIRE ACONDICIONADO DE PARED
DEAR CUSTOMER
Congratulations for your purchase!
Please read this manual carefully, and keep it for future reference.
If you need extra support, please write to info@premiermundo.com
INSTRUCTION MANUAL
AA-1821
AA-1823
R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AA-1821 and is the answer not in the manual?

Questions and answers

Summary of Contents for Premier AA-1821

  • Page 1 INSTRUCTION MANUAL AIRE ACONDICIONADO DE PARED AA-1821 AA-1823 DEAR CUSTOMER Congratulations for your purchase! Please read this manual carefully, and keep it for future reference. If you need extra support, please write to info@premiermundo.com...
  • Page 2 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM...
  • Page 3 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM ASW-H09A2/*(Q) ASW-H12A2/*(Q) ASW-H18B2/#(Q) ASW-H24B2/#(Q) ASW-H24B2/#(Q) ASW-H09A2/*(Q) ASW-H12A2/*(Q) ASW-H18B2/#(Q) AS-H09A2/*(Q) AS-H12A2/*(Q) AS-H18B2/#(Q) AS-H24B2/#(Q) 9000/2500 24000/ 7000 12000/3300 18000/5300 9600/2800 13000/3850 19800/5800 26300/ 7700 (m/h) 1100 1PH 208V-230V~/60Hz 1270 2700 2000 1230 2650 2000 12.5 12.1 1410 1910 3830 3000 19.3 14.9 16.5X80.2X26.2...
  • Page 4 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM ASW-09A2/*(Q) ASW-12A2/*(Q) ASW-18B2/#(Q) ASW-24B2/#(Q) ASW-12A2/*(Q) ASW-18B2/#(Q) ASW-09A2/*(Q) ASW-24B2/#(Q) AS-12A2/*(Q) AS-18B2/#(Q) AS-24B2/#(Q) AS-09A2/*(Q) 9000/2500 12000/3300 18000/5300 24000/7000 1100 (m/h) 1PH 208V-230V~/60Hz 1230 2000 2600 3000 3830 1410 1870 14.9 19.3 16.5X80.2X26.2 17.6X89X29.6 19X99.5X32 19X115.3X33.5 10.5 26~40 30~41 44~49 43~46 26X76X54 30X80X69 Exterior...
  • Page 5 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM Pagina 3...
  • Page 6 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM Pagina 4...
  • Page 7 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM ASW-(H)18B2/M ASW-(H)24B2 AS-(H)18B2/# AS-(H)24B2/# Pagina 5...
  • Page 8 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM Pagina 6...
  • Page 9 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM Pagina 7...
  • Page 10 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM Pagina 8...
  • Page 11 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM Pagina 9...
  • Page 12 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM Pagina 10...
  • Page 13 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM Pagina 11...
  • Page 14 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM 15998001531...
  • Page 15 INSTRUCTION MANUAL SPLIT TYPE ROOM AIR CONDITIONER AA-1821 AA-1823 DEAR CUSTOMER Congratulations for your purchase! Please read this manual carefully, and keep it for future reference. If you need extra support, please write to info@premiermundo.com...
  • Page 16: Table Of Contents

    WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM CONTENTS Specifications -----------------------------------------------------------1 Parts Description--------------------------------------------------------5 Outdoor Unit -------------------------------------------------------6 Usage -------------------------------------------------------------------6 Working condition -------------------------------------------------6 Remote controller usage ------------------------------------------6 --------------------------------------------6 Hand control operation Items of attention-------------------------------------------------------7 Checking before usage --------------------------------------------7 Safety rules ---------------------------------------------------------7 Optimal operation --------------------------------------------------8 Maintenance ------------------------------------------------------------9 Failure type and methods of resolution --------------------------9 Non-air conditioner trouble -------------------------------------12...
  • Page 17: Specifications

    WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM ASW-H12B4/* ASW-H07B4/* ASW-H09A4/* ASW-H12A4/* ASW-H07B4/* ASW-H09A4/* ASW-H12A4/* ASW-H12B4/* AS-H09A4/* AS-H12A4/* AS-H07B4/* AS-H12B4/* (W/Btu/h) 2500/9000 3200/12000 2300/7000 3500/12000 (W/Btu/h) 2800/9600 2650/9000 4000/13600 3520/13000 1PH 220V-240V ~/50Hz 1270 1300 1230 1320 1910 1920 1410 1350 16.5X80.2X26.2 17.6X89X29.6 26~40 26~39 30~41 30~41 26X76X54 6.35X0.6X 3000(3600/4000/5000/6000)
  • Page 18 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM ASW-07B4/* ASW-09A4/* ASW-12A4/* ASW-12B4/* ASW-09A4/* ASW-12A4/* ASW-07B4/* ASW-12B4/* AS-09A4/* AS-12A4/* AS-07B4/* AS-12B4/* (W/Btu/h) 2300/7000 2500/9000 3200/12000 3500/12000 (W/Btu/h) 1PH 220V-240V ~/50Hz 1230 1320 1910 1920 1230 1320 17.6X89X29.6 16.5X80.2X26.2 30~41 26~40 30~41 26~39 26X76X54 6.35X0.6X3000(3600/4000/5000/6000) 9.52X0.6X3000(3600/4000/5000/6000) 198~264 10~15 12~17 14~23 16~24...
  • Page 19 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM ASW-H18A4/# ASW-H18B4/# ASW-H24A4/# ASW-H24B4/# ASW-H18A4/# ASW-H18B4/# ASW-H24A4/# ASW-H24B4/# AS-H18B4/# AS-H24B4/# AS-H18A4/# AS-H24A4/# (W/Btu/h) 4800/16000 5300/18000 6000/22000 7000/24000 (W/Btu/h) 5400/18500 5800/19800 6600/22500 7700/26300 1000 1100 1PH 220V-240V ~/50Hz 1950 2000 2400 2700 1850 2000 2300 2780 12.5 10.5 12.3 2930 3000 3450...
  • Page 20 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM ASW-18A4/# ASW-18B4/# ASW-24A4/# ASW-24B4/# ASW-18A4/# ASW-18B4/# ASW-24A4/# ASW-24B4/# AS-18B4/# AS-24B4/# AS-18A4/# AS-24A4/# (W/Btu/h) 4800/16000 5300/18000 6000/22000 7000/24000 (W/Btu/h) 1000 1100 1PH 220V-240V ~/50Hz 1950 1950 2400 2700 12.3 2930 2930 3450 3830 14.8 14.8 17.4 19.3 20X100.5X32 21.5X115.0X32 41~43 43~46 44~46...
  • Page 21: Parts Description

    WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM Parts Description Indoor Unit Indoor Unit Installation board Middle frame Indication light and signal receiver Front panel Horizontal airflow direction vane Vertical airflow direction vane(inner) Air filter Pipe protection ring Drain pipe Outdoor Unit Outdoor Unit Pipe and Drain pipe Cut-off valve Outlet cover Fig.1...
  • Page 22: Usage

    WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM Outdoor Unit Usage Working condition Maximum: DB/WB 32 /23 Indoor DB/WB 21 /15 Minimum: Cooling Maximum: 43 /26 DB/WB Outdoor 21 /15 DB/WB Minimum: Maximum: 27 - DB/WB Indoor 20 - DB/WB Minimum: Heating Maximum: 24 /18 DB/WB Outdoor -5 /-6 DB/WB...
  • Page 23: Items Of Attention

    WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM Wind direction adjusting 1.Horizontal wind direction adjusting Use hands to move the vane and change the horizontal wind direction. Note: Adjust the horizontal wind direction before the air-conditioner starts. Don t reach your finger into air-out window when the air-conditioner is operating. 2.Vertical wind direction adjusting Refer to Remote Controller Usage Instruction...
  • Page 24: Optimal Operation

    WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM Optimal operation Pay attention to the following items so as to ensure optimal operation of the system, detailed operation see the relevant content. Please set the scheduled operation time with the remote controller. Set the suitable temperature for a comfortable environment. Don't make the room too cold or too hot.
  • Page 25: Maintenance

    WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM Danger Don't touch the swinging wind vanes, Don't put your hand or stick-shaped objects or it may clamp your finger and damage into the air outlet of the indoor and outdoor the driving parts of the wind vanes. unit, otherwise, the rotating fan at high speed may cause injury to you.
  • Page 26: Non-Air Conditioner Trouble

    WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM In case the following situations, please deal with it according to the following methods, if it does not work, please contact distributor and inform the detailed failure. Causes Failure Methods of resolution Power supply failure Wait for the recovery of power supply The power switch is released Switch on the power Start-up...
  • Page 27 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM 2.White steam comes out from the indoor unit During the cooling operation ,under high relative humidity indoors, white steam may come out due to the high humidity and temperature difference of air inlet and outlet. The air-conditioner convert to heating operation after the frost dissolving, the moisture due to frost dissolving is discharged in form of steam.
  • Page 28: Cleaning

    WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM Cleaning Warning: For the purpose of safety, please turn off the air-conditioner and cut off the power supply before cleaning. Cleaning the indoor unit 1.Wipe the indoor unit with dry cloth . 2.If the indoor unit is very dirty, please wipe with wet cloth dipped by cold water. 3.The panel of indoor machine may be taken off.
  • Page 29: Installation

    WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM Installation The installation of air-conditioner should meet Installation Instruction . The machine must be installed correctly by professional technicians according to the Installation Instruction . Guide of customer The customer should have a qualified power supply coincident with the tag of the air conditioner, its voltage should be in the range of 90-110% of its rated voltage.
  • Page 30 WWW.PREMIERMUNDO.COM WWW.PREMIERMUNDO.COM 15998003545 T01022...

This manual is also suitable for:

Aa-1823

Table of Contents