Dual capacity, 3 to 6 tons

Advertisement

Dual Capacity, 3 to 6 Tons, R410A
Installation and Maintenance Manual
Table of
Contents
Model
Nomenclature
Safety
power switches to the indoor unit. If applicable, turn off the accessory heater power switch.
Considerations
Electrical shock could cause personal injury.
pressure and electrical components. Only trained and qualified service personnel should install, repair
or service heating and air conditioning equipment.
and replacing filters. All other operations should be performed by trained service personnel. When
working on heating and air conditioning equipment, observe precautions in the literature, tags and labels
attached to the unit and other safety precautions that may apply.
operations and have a fire extinguisher available.
Moving and
information on the carton. Do not stack more than three units in total height. Vertical units may be stored
Storage
one upon another to a maximum height of two units. Do not attempt to move units while stacked. When
the equipment is received, all items should be carefully checked against the bill of lading to be sure all
crates and cartons have been received. Examine units for shipping damage, removing the units from the
cartons if necessary. Units in question should also be internally inspected. If any damage is noted, the
carrier should make the proper notation on the delivery receipt, acknowledging the damage.
E
048
T
L 1 0 1 C B D S S A
Model Type
Premier - R410A
Unit Capacity
MBTUH
Discharge Air Configuration
T = Top Discharge Vertical
B = Bottom Discharge Vertical
E = End Discharge Horizontal
S = Side Discharge Horizontal
Return Air Configuration
L = Left
R = Right
Voltage
1 = 208-230/60/1
Hot Water Options
0 = None
1 = Hot Water Generation With
Factory Installed Pump
WARNING: Before performing service or maintenance operations on a system, turn off main
Installing and servicing heating and air conditioning equipment can be hazardous due to system
Untrained personnel can perform the basic maintenance functions of cleaning coils and cleaning
Follow all safety codes. Wear safety glasses and work gloves. Use a quenching cloth for brazing
Move units in the normal "up" orientation. Horizontal units may be moved and stored per the
E Series
Vintage
A = Current
Non-Standard Option Details
Non-Standard Options
Filter Options
D =1" Pleated Disposable
Sound Kit
B = Blanket (standard)
Coax Options
C = Copper
N = Cupronickel
Blower Options
1 = ECM Blower
2 = Oversized ECM Blower Option
(048 Only)
P/N 96P557A06
07/02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Premier E Series

  • Page 1: Table Of Contents

    P/N 96P557A06 07/02 E Series Dual Capacity, 3 to 6 Tons, R410A Installation and Maintenance Manual Unit Electrical Data 16 Model Nomenclature 1 Table of Electronic Thermostat 16 Safety Considerations 1 Contents Microprocessor Control Operation 16-19 Moving and Storage 1...
  • Page 2: Physical Data

    PREMIER E SERIES DUAL CAPACITY INSTALLATION AND MAINTENANCE MANUAL Physical Data Vertical Units MODEL E036 E048 E060 E072 Fan Wheel 11 X 10 11 X 10 11 X 10 11 X 10 Fan Motor ECM-1/2 ECM-1/2* ECM-1 ECM-1 Compressor Bristol Twin Single...
  • Page 3 PREMIER E SERIES DUAL CAPACITY INSTALLATION AND MAINTENANCE MANUAL SETTING VERTICAL UNITS Vertical units are available in left or right air return configurations. Top flow vertical units should Vibration Absorbing be mounted level on a vibration absorbing pad Mesh slightly larger than the base to provide isolation between the unit and the floor.
  • Page 4 PREMIER E SERIES DUAL CAPACITY INSTALLATION AND MAINTENANCE MANUAL Figure 3– Optional Filter Rack Horizontal Filter Rack MODEL Model No. 37.1 20.1 DCH2037 E036, 048 42.1 20.1 DCH2042 E060 47.1 20.1 DCH2048 E072 1" duct connection is provided. Construction is air tight.
  • Page 5 PREMIER E SERIES DUAL CAPACITY INSTALLATION AND MAINTENANCE MANUAL Figure 4A Stainless Locking Steel Ring Snap Ring Gasket Support Gasket Sleeve Material Figure 4B - The female locking ring is threaded onto the pipe threads which hold the male pipe end against the gasket and seals the joint.
  • Page 6: Closed Loop Ground Source Systems

    These terminals are polarity dependant (see Figure 7 on page 7). The loop pump(s) may be powered from either Premier unit, whichever is more convenient. If either unit calls, the loop pump(s) will automatically start. The use of two units on one flow center is generally limited to a total of...
  • Page 7 PREMIER E SERIES DUAL CAPACITY INSTALLATION AND MAINTENANCE MANUAL Figure 6 - Closed Loop: Ground Source Application - Single unit with Flow Center Auxiliary Heat ® GeoLink LOOP Supply Polyethylene w/ ® Armaflex Unit Supply Insulation Flexible Duct Collar Auxiliary...
  • Page 8: Open Loop Groundwater Systems

    PREMIER E SERIES DUAL CAPACITY INSTALLATION AND MAINTENANCE MANUAL Open Loop OPEN LOOP SYSTEMS Groundwater For open loop/groundwater systems or systems that do not contain an antifreeze solution, NOTE: set SW2-Switch #2 to the “WELL” position, (See schematic on pages 14 and 15).
  • Page 9 PREMIER E SERIES DUAL CAPACITY INSTALLATION AND MAINTENANCE MANUAL Figure 9 - Open loop solenoid valve connections Typical two stage external 24V water valve utilizing one motorized valve ( type VM) and one pilot operated solenoid valve (BPV100 or PPV100)
  • Page 10: Desuperheater Connection

    PREMIER E SERIES DUAL CAPACITY INSTALLATION AND MAINTENANCE MANUAL WATER TANK PREPARATION Desuperheater A family of four should have a water heater with a minimum 50-gallon capacity. For families of Connection more than four, use an 80-gallon water heater or two 50-gallon water heaters connected in a series as shown in Figure 12 on page 11.
  • Page 12: Initial Desuperheater Start Up

    If so equipped, unscrew the indicator plug on the motor end of the pump (located in the Premier E unit) until all air is purged from the pump, then tighten the plug. Use vent couplings to bleed air from the lines.
  • Page 13 PB1 in the unit electrical box as shown in Figure 10 below. The pumps will automatically be cycled as required by the unit or by a slave signal from another Premier E unit sharing the flow center (see Figure 7 on page 7).
  • Page 14: Wiring Schematic

    PREMIER E SERIES DUAL CAPACITY INSTALLATION AND MAINTENANCE MANUAL Premier E Series Bristol Dual Capacity Wiring Schematic 208-230/60/1 - ECM2 Blower BRISTOL DUAL CAPACITY Protector 97P644B01 01/18/01 Part 1 of 2 Blue Start Blue COMP Main CAPACITOR Black White Blue...
  • Page 15: Wiring Schematic

    PREMIER E SERIES DUAL CAPACITY INSTALLATION AND MAINTENANCE MANUAL Premier E Series Bristol Dual Capacity Wiring Schematic 208-230/60/1- ECM2 Blower 97P644B01 01/18/01 Part 2 of 2 CSA installed units only Local codes may require a single source of power supply...
  • Page 16: Unit Electrical Data

    See instructions enclosed in the thermostat for detailed installation and operation information. DIP switch SW2-#8 is required to be in the OFF position for the Premier E control to NOTE: recognize the 24VAC thermostat inputs. SW2-#8 must be ON when using the TA32E12 thermostat.
  • Page 17 Fan RPM The Premier E control board monitors fan RPM to sense if the fan is not operating. This lockout mode occurs if the fan RPM falls below the low RPM limit (100 RPM) for 30 continuous seconds.
  • Page 18 This dip switch allows field selection as to what type of thermostat is being connected to the Premier E control. If using a TA32E12, the dip switch must be in the “ON” position. The dip switch should be in the “OFF” position for all 24VAC thermostats.
  • Page 19: Blower Speed

    H speed, respectively SW1 On A 12 position DIP switch package on the Premier E control allows the airflow levels to be set for Low, Medium, and High speed when using the ECM2 blower motor. Only three of the DIP switches can be in the “ON” position. The first “ON” switch (the lowest position number) determines the “Low Speed Fan”...
  • Page 20: Unit Start-Up

    PREMIER E SERIES DUAL CAPACITY INSTALLATION AND MAINTENANCE MANUAL BEFORE POWERING UNIT, CHECK THE FOLLOWING: Unit Start Up High voltage is correct and matches nameplate Fuses, breakers and wire size correct Low voltage wiring complete Piping completed and water system cleaned and flushed...
  • Page 22: Preventive Maintenance

    PREMIER E SERIES DUAL CAPACITY INSTALLATION AND MAINTENANCE MANUAL WATER COIL MAINTENANCE Preventive Maintenance Keep all air out of the water. An open loop system should be checked to ensure that the well head is not allowing air to infiltrate the water line. Lines should always be airtight.
  • Page 23: Unit Operating Pressures

    PREMIER E SERIES DUAL CAPACITY INSTALLATION AND MAINTENANCE MANUAL If control responds improperly: • Ensure that component being controlled is functioning (Compressor, Blower, Reversing valve, etc.). • Ensure that wiring from control to the component is functioning (use the diagnostic outputs mode).
  • Page 24 Installation and Maintenance Manual P/N 96P557A06 Rev. 07/02 WaterFurnace has a policy of continuous product research and development and reserves the right to change design and specifications without notice. WaterFurnace and Premier are registered trademarks of WaterFurnace International, Inc. ©2002 WaterFurnace International, Inc.

This manual is also suitable for:

E060E072E036E048

Table of Contents

Save PDF