Replacing The Globrite Light Assembly (After Electrical Requirements Are Met) - Pentair Globrite Installation And User Manual

White led light for pool and spa
Hide thumbs Also See for Globrite:
Table of Contents

Advertisement

REPLACING THE GLOBRITE
(AFTER ELECTRICAL REQUIREMENTS ARE MET)
The following removal and installation instructions describe how to remove and install
the GloBrite
light assembly.
THE GLOBRITE LIGHT IS A NON-SERVICEABLE LIGHT. THE
COMPLETE LIGHT ASSEMBLY MUST BE REPLACED.
Failure to bring the pool or spa's electrical system up to code requirements
before installing the underwater light will create an electrical hazard which
could result in death or serious injury to pool users, installers, or others due to
electrical shock, and may also cause damage to property.
1.
Switch off electrical switch or circuit breaker at the source,
2.
Remove Junction Box or Transformer cover. Disconnect the light wires and
attach a fish tape to the existing light power cord. This will assist in pulling
the replacement light power cord through the conduit back to the junction
box.
3.
Remove the GloBrite light assembly from the pool or spa water: Using
the provided installation tool (P/N 620057), rotate the light assembly
counter-clockwise about a 1/8th turn to release the light from the niche as
shown on page 9).
4.
Slowly pull the light and attached power cord (with attached fish tape) out of
the niche. Pull the light's power cord and fish tape out of the niche and
place the light on the deck.
5.
Attach the new light power cord to the fish tape and carefully feed the fish
tape and cable to the junction box.
6.
Install the light into the niche: Place the light installation tool over the front
of the light. Turn the tool and light clockwise while pushing inward, until you
feel the stop point. This indicates the light is properly seated, locked and
the electrical conduit, is completely sealed (see page 9).
Note: If the light does not turn smoothly, pull the light slightly out and be
sure that it's seated properly and the niche is free of debris, then install the
light as described in step 5.
7.
Connect the two (2) conductors to the corresponding circuit wires in the
Junction Box (black wire to power, white wire to common) and secure the
Junction Box cover in place.
8.
Final check for proper GloBrite
switch or circuit breaker to the 12 VAC transformer and the switch that
operates the light itself. The light should illuminate when 12 VAC power is
applied. If not recheck the installation steps.