14. Voltikus Rear Panel Explained

31
32
33
31. Fuse compartment
Takes two fuses: 0.8A, 250 VAC, 5 mm x 20 mm, Type F.
32. Power switch
Toggles power on/off.
33. IEC AC Input C14 Male Connector
For use with supplied AC Power cable.
34. Ground/Lift switch
Toggles grounded or lifted state.
35. 18 VDC Output
For use with supplied Antelope DC Power cable only.

15. Replacing a Voltikus fuse

If the power light is not illuminated and the Voltikus is plugged into a working AC power outlet with
the power switch in the on position, the fuse may need to be replaced.
● Disconnect the power cord from the electrical outlet.
● Insert a flat blade screwdriver into the notch at the bottom edge of the fuse holder (31) to
release it. (See image below).
● Remove the fuses from the fuse holder. Replace them with 0.5A 250V Time Lag (Slo-Blo)
Littelfuse Inc. P/N: 0218.500MXP