Download Print this page

Phontech Communication 4000 User Manual page 9

Batteryless telephone system

Advertisement

PHONTECH
RELAY MODULE (PCB 99400-011)
A relay module for activation of external signal device can be installed in the following units:
- 4050 / 4051 / 4055 / 4060 / 4061
The relay module is to be mounted by the installer. The unit is delivered separately, and is to be
plugged into the appropriate telephone unit.
• Open the backbox on the telephone unit.
• Plug the relay unit into the receptacle on the PCB inside the telephone. Make sure the
connector pins make contact.
• Snap the stand off`s (2pcs) into the holes in the PCB.
• Make the connections according to the installation drawings 99400-017-EC or 99400-018-
EC.
• If DC voltage is used, make sure the polarity is correct. (Indication on the dwgs. 99400-
017-EC and 99400-018-EC)
.
Handbook page
Doc.No.: 99400-000-DE
Page 6 of 14
9/43

Advertisement

loading