6. INSTALLATION.

• SYSTEM CONFIGURATION:
The system is to be configured by the installer. Each telephone must be connected to
different "call number" with regards to the Line selector (rotary switch). This is done by
means of links in each telephone. The link is to be connected between terminal 13 and the
desired call number. (1-12)
Consult the installation drawing 99400-017-EC and 99400-018-EC for examples.
• MOUNTING:
The telephone units (all types) are delivered for flush mounting. Optional wall mounting boxes
are delivered upon request.
PhonTECH highly recommends the use of junction boxes for the external cable distribution.
The junction box must be located as close to the amplified telephone (4051/4061) unit as
possible.
On request PhonTECH will supply the junction box. Type 4052 and/or 4053.
The sub-units (9000/4018/) are delivered with wall mounting box as standard.
Ref. actual Data sheet for each unit and Technical specification for mounting details.
• COMPASS SAFE DISTANCE
Compass type
Standard
Steering
Stand by steering Emergency
• CABLE TERMINATION.
All termination according to the External Cabling diagram (example) 99400-017/18-EC. In
most cases Phontech will supply a detailed custom designed "system cable diagram" for the
actual delivery.
• CABLE REQUIREMENTS.
All cables used with the Batteryless Telephone System to be of approved ship cable type.
ESPECIALLY IMPORTANT:
o Common outer screen.
o Individually twisted pairs.
.
Safe distance
BTS-4050/4051 / 4060/4061
1,7m
0,95m
Handbook page
Doc.No.: 99400-000-DE