Model: HRF-660W/U
5. Loosening 2 screws fixed to ceiling of inner liner;
6. Pull out the electric damper, wind passage and the wind passage cover;
7. After replaced the disabled parts, assemble in reverse order of disassembly.

3.4. Wind passage cover assembly and lamp in freezer chamber

1. Unplug the power cord from the outlet;
2. Remove the freezer shelf;
3. Remove the lamp cover;
4. The bulb can be replaced;
5. Loosening 2 screws f ixed the cover and pull out the top
freezer air tower;
6. Pull out the bottom freezer air tower and unplug the
sensor cable;
7. Pull out the freezer rack, unplug the fan motor cable and
separate the fan motor cover and the rack.
8. Pull out the freezer air shutter;
9. Unplug the defrost sensor cable and replace it;
10. Assemble in reverse order of disassembly.