J. AUDIO OUTPUT (A/C HEAD TILT & HEIGHT ADJUSTMENT)
TEST POINTS
MEASURING EQUIPMENT
a. Connect the OSCILLOSCOPE to the AUDIO OUTPUT JACK.
b. Play back the ALIGNMENT TAPE (NTSC: DN1 (SP , 1KHz), PAL: DP1 (SP , 1KHz)).
c. Check the AUDIO OUTPUT SIGNAL is -9~-3dBm.
d. If the requirement "c" is not satisfied, adjust the A/C HEAD TILT SCREW and A/C HEAD HEIGHT NUT
to obtain the maximum audio output. (Fig. 5-3)
K. A/C HEAD AZIMUTH ADJUSTMENT
a. Connect the OSCILLOSCOPE to the AUDIO OUTPUT JACK.
b. Play back the ALIGNMENT TAPE (NTSC: DN2 (SP , 7KHz), PAL: DP2 (SP , 6KHz)).
c. Adjust the A/C HEAD AZIMUTH SCREW to obtain the audio output -9~-3dBm. (Fig. 5-3)
d. Repeat the process "H. DRUM ENTRANCE/EXIT".
TEST POINTS
MEASURING EQUIPMENT
AUDIO OUTPUT
OSCILLOSCOPE
AUDIO OUTPUT
OSCILLOSCOPE
35
AUDIO OUTPUT JACK
AUDIO OUTPUT JACK