FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
A. This appliance is equipped with an ignition device which automatically
lights the pilot. Do not try to light the pilot by hand.
B. BEFORE OPERATING smell all around the appliance area for gas. Be
sure to smell next to the floor because some gas is heavier than air and
will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any telephone in your
building.
• Immediately call your gas supplier from a neighbor's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use
tools. If the knob will not push in or turn by hand, don't try to repair it,
call a qualified service technician. Force or attempted repair may result
in a fire or explosion.
D. Do not use this appliance if any part has been under water, immediately
call a qualified service technician to inspect the appliance and to replace
any part of the control system and any gas control which has been
under water.
OPERATING INSTRUCTIONS
1. Stop! Read the safety information above on this label.
2. Turn off all electric power to appliance.
3. Set the thermostat to the lowest setting.
4. This appliance is equipped with on ignition device which automatically
lights the pilot. Do not try to light the pilot by hand.
5. Slide the switch on the left side of the gas valve to the "OFF" position.
6. Wait five (5) minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow "B" in the
safety information above on this table. If you don't smell gas, go to the
next step.
7. Slide the switch on the left side of the gas valve to the "ON" position.
8. Set thermostat to desired setting.
9. Turn on all electric power to the appliance.
10. If the appliance will not operate, follow the instructiolns "To Turn Off Gas
To Appliance" and call your service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
1. Turn off all electric power to the appliance.
2. Set the thermostat to lowest setting.
3. Slide the switch on the left side of the gas valve to the "OFF" position.

THERMOSTAT ADJUSTMENT

Before adjusting thermostat(s), turn off power supply to the water heater.
The thermostat dial is adjusted to approximately 120°F when shipped from the
factory. When adjusting the thermostat, it should be remembered that lower
temperature settings are more energy efficient. The thermostat cover, on the
right side of the gas valve, must be removed when the thermostat is adjusted.
To adjust the thermostat turn the dial colckwise with a screwdriver until the
minimum acceptable temperture is set. It is suggested that the starting point
setting not exceed the 120°F (49°C) or "HOT" setting on the thermostat.
CAUTION
Figure 13
TEMPERATURE SETTING
APPROXIMATELY
120°F (49°C)
Hotter water increases the risk of scald injury. Scalding may occur
within five (5) seconds at a temperature setting of 135°F (57°C). To
protect against hot water injury, install an anti-scald tempering valve
in the water system. This valve will reduce point of discharge
temperature by mixing cold and hot water in branch water lines. A
licensed plumbing professional or local plumbing authority should be
consulted.
Note: This water heater is equipped with an energy cut out device to
prevent overheating. Should overheating occur or the gas supply fail
to shut off, turn off the manual gas control valve to the appliance and
call a qualified service technician.
Note: Whenever the water heater is filled with cold water, condensate
will form on the cool tank surface and drops of water will fall on the hot
burner and combustion chamber surfaces producing a "sizzling" noise.
Condensation is normal and does not indicate a leak. It will disappear
when the tank becomes heated.

BURNER FLAME CHECK

Cast Iron Burner: At the time of installation and at periodic intervals (not
more than 6 months), a visual check of the main burner and pilot flames
should be made to determine if they are burning properly. For ideal operation,
the gas and air must be properly proportioned. The proper air-gas mixture is
obtained by adjusting the air shutter on the mixer face of the main burner (See
Figure 14). To adjust for proper burning, loosen the air shutter nut (if provided),
rotate shutter to close the opening in the burner then slowly rotate the shutter
until the yellow tips disappear and the flame becomes blue. On 75 gallon
models fired on LPG or propane, adjust the air shutter as described above until
the yellow flame is minimized (note-the burner flame may contain a mixture of
yellow and blue). Tighten the air shutter nut. Too much air will cause the flame
to lift off the burner ports and create noisy operation. Too little air will result in
soot formation. The main burner flame should light smoothly from the pilot.
Steel Burner: These models are equipped with self adjusting air mixture and
do not have an adjustable air shutter (See Figure 14). At periodic intervals a
visual check of the main burner and pilot flames should be made to determine
if they are burning properly. The main burner flame should light smoothly from
the pilot.