Atlas ECS-204 Owner's Manual

20a power conditioner & sequencer

Advertisement

Quick Links

ECS-204
Owner's Manual
20A Power Conditioner & Sequencer
ECS-204
20A Power Conditioner & Sequencer
Detailed Product Information
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 1 –
AtlasSound.com
Specifications are subject to change without notice.

Advertisement

Table of Contents
loading

Summary of Contents for Atlas ECS-204

  • Page 1 ECS-204 Owner’s Manual 20A Power Conditioner & Sequencer ECS-204 20A Power Conditioner & Sequencer Detailed Product Information 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 – 1 – AtlasSound.com Specifications are subject to change without notice.
  • Page 2: Table Of Contents

    ECS-204 Owner’s Manual 20A Power Conditioner & Sequencer Table of Contents Important Safety Instructions ......................... 3 Introduction ............................5 Key Features ............................6 Applications ............................6 Front Panel ............................. 7 Rear Panel ............................10 Installation ............................. 13 AC Power Cord Retainer System ......................14 Troubleshooting .............................
  • Page 3: Important Safety Instructions

    ECS-204 Owner’s Manual 20A Power Conditioner & Sequencer Important Safety Instructions The lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage “ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
  • Page 4 Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the AC outlet and contact Atlas Sound. Do not to attempt to continue operation with the product as this may cause fire or electric shock: •...
  • Page 5: Introduction

    Another factor would be from voltage drops in AC lines due to long transmissions. The ECS-204 will not only inform you if one of these conditions occurs, but under extreme variances in the AC Mains, it will shut the power to the equipment Off.
  • Page 6: Key Features

    Applications The ECS-204 was designed to be flexible with features that allow it to be used in a variety of applications. The sequenced outputs allow the turning of equipment On and Off in a particular order, to eliminate an in rush of current and audible pops that often occur with non-sequenced power strips.
  • Page 7: Front Panel

    Front Panel Features 1. Unswitched AC Outlets – The two 120VAC outlets are always “Live” when the ECS-204 power cord is plugged into an AC mains power source and voltage is present. If voltage is present at the outlets, it will be displayed on the AC Mains Voltage Meter.
  • Page 8: Front Panel Features

    High AC Line Mains – The Abnormal Voltage LED will flash between 128VAC and 132VAC indicating possible damage may occur to equipment due to high AC Mains voltage. The ECS-204 outlets will remain active but the LED will stay flashing even if the voltage returns to a normal operating range.
  • Page 9 12. System ON Indicator – When the ECS-204 is activated the system ON LED will be illuminated. 13. Slave Mode Indicator – If the ECS-204 is selected to be a slave unit, the Slave Mode LED will illuminate indicating that there is more than one ECS-204 connected to the trigger sequencing.
  • Page 10: Rear Panel

    ECM-20SH. Contact Atlas Sound for AC outlet options. 6. Sequence 4 Output – The ECS-204 can handle 20A of current before the breaker opens. If 20A is not enough current to support the power requirements, this output can be used to activate an additional power outlet such as the ECM-20SH.
  • Page 11 7. Switch Configuration Settings – There are 5 Dip Switches that control Sequence Delay Timing, System link combining of 2 or 3 ECS-204 units together and the EVS Reset mode. Follow the chart in the manual or the chart located on the top cover of the unit for operation settings.
  • Page 12: Rear Panel Features

    (Front) 8. Remote DC Voltage 5- 24V Activation – The ECS-204 can be remotely activated from hundreds of feet away using a RMT V IN for activation. DC voltages ranging from 5V DC to 24V DC can be applied to the two terminal connections on the Remote Activation...
  • Page 13: Installation

    Before installing we strongly suggest you read the entire manual to ensure you benefit from all the features of the ECS-204. The ECS-204 can be placed on a shelf or rack mounted in a standard 19" width rack. Placement within a rack is not critical but the rack should be within 6' of dedicated 20A AC outlet.
  • Page 14: Ac Power Cord Retainer System

    20A Power Conditioner & Sequencer AC Power Cord Retainer System Your Atlas Power product comes with an AC Mains Power Cord Retainer System. This system prevents the power cord from being removed without the use of a screwdriver. Follow these steps for installation.
  • Page 15: Troubleshooting

    Action Needed - If this happens, the ECS-204 will shut off and the unit will need to be repaired or replaced. It is important to have all equipment that was connected to that AC Mains Line inspected for proper operation.
  • Page 16: Specifications

    ECS-204 Owner’s Manual 20A Power Conditioner & Sequencer Specifications Type Power Sequencer, Power Conditioner & Suppressor Sequencer Sections 3 Internal Sections and 1 External Output Load Rating Safety Listing ETL (UL 60065 Standard) Front Panel AC Outlets 2 Unswitched Lights...
  • Page 17 ECS-204 Owner’s Manual 20A Power Conditioner & Sequencer Specifications Technical Data Current Rating 20 amps Power Consumption 12 watts Operating Voltage 102 - 132VAC Delay Adjustments (Assignable) Min 3 Seconds to 15 Seconds, Max 6 Seconds to 2 Minutes High Voltage Surge Protection...
  • Page 18 ECS-204 Owner’s Manual 20A Power Conditioner & Sequencer Notes: 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 AtlasSound.com – 18 – Specifications are subject to change without notice.
  • Page 19 ECS-204 Owner’s Manual 20A Power Conditioner & Sequencer Notes: 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 – 19 – AtlasSound.com Specifications are subject to change without notice.
  • Page 20: Warranty

    A PARTICULAR PURPOSE. Atlas Sound does not assume, or does it authorize any other person to assume or extend on its behalf, any other warranty, obligation, or liability. This warranty gives you specific legal rights and you may have other rights which vary from state to state.

Table of Contents