1. This pump is designed for home sump applications.
2. This pump will provide years of trouble-free service when properly installed, maintained, and used.
However, inadequate electrical power to the pump, dirt, or blockage by ice or debris may cause the pump to
fail, eventually bringing about additional water damage. To minimize the potential for water damage due to
pump failure, please carefully read the manual and follow the instructions regarding common pump
problems and remedies or call 1-800-346-7611.
3. For safety, the pump motor has an automatic resetting thermal protector that automatically will turn off the
pump if it becomes too hot. Overuse of this feature will damage the pump and will void the warranty.
4. Once the thermal protector detects that the pump has cooled to a safe temperature, it will allow the pump
to operate normally. If the pump is plugged in, it may restart unexpectedly.
Additional Safety Precautions
1. Know the pump applications, limitations, and potential hazards.
2. Make certain the electrical power source is adequate for the requirements of the pump.
3. ALWAYS disconnect the power to the pump before servicing.
4. Release all pressure (drain all water) within system before servicing any component.
5. Secure discharge line before starting pump. An unsecured discharge line will whip, possibly causing personal
injury and/or property damage.
6. Secure the pump on a solid base to keep the pump vertical and above mud and sand during operation to
maximize pumping efficiency and prevent clogging and premature pump failure.
7. Check that all pipe connections are tight to minimize leaks.
8. Connect the pump DIRECTLY to a grounded, GFCI outlet on a 15-Amp or larger dedicated circuit breaker.
9. Extension cords should not be used.
10. Periodically inspect the pump and system components to be sure the pump inlet is free of mud, sand, and
debris. DISCONNECT THE PUMP FROM THE POWER SUPPLY BEFORE INSPECTING.
11. Wear safety glasses at all times when working on the pump.
12. Follow all electrical and safety codes, particularly the National Electrical Code (NEC) and in the workplace,
the Occupational Safety and Health Act (OSHA).
13. This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved
3-conductor cord and 3-prong grounded plug. DO NOT REMOVE THE GROUND PIN UNDER ANY
CIRCUMSTANCES. The 3-prong plug must be directly inserted into a properly installed and grounded
3-prong, grounding-type receptacle. Do not use this pump with a 2-prong wall outlet. Replace the 2-prong
outlet with a properly grounded 3-prong receptacle (a GFCI outlet) installed in accordance with the National
Electrical Code and local codes and ordinances. All wiring should be performed by a qualified electrician.
14. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do
not use damaged or worn cords.
WATER SOURCE LLC
Warns of hazards that CAN cause serious personal injury, death or major property
damage if ignored.
SEE BELOW FOR LIST OF WARNINGS