Danish Interpretation Systems List of Contents List of Contents... 3 Important ... 4 Compliancy... 4 Installation precautions ... 4 Cleaning ... 4 Repacking ... 4 Warranty ... 4 Description of the DCS 6000 system ... 5 Features... 5 System components... 6 Central equipment etc...
Danish Interpretation Systems Important Compliancy The equipment has been tested and found to comply with the limits of the following standards for digital devices: EN55103-1 (Emission) EN55103-2 (Immunity) FCC rules part 15, class A (Emission) This device complies with part 15 of the FCC rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference...
Danish Interpretation Systems Description of the DCS 6000 system Features The DCS 6000 system has the following main features: Fully digital Excellent sound quality “State of the Art” fully digital integrated interpretation, discussion and voting system offering interpretation, language distribution, conference microphone and voting facilities with attendance check with Chip Card ™.
Danish Interpretation Systems System components The CU 6005/6010 Central Units support all available units in the DCS 6000 series: Central equipment etc. EX 6010 Extension Unit PS 6000 Power Supply AO 6004 Audio Output box AO 6008 Audio Output box RP 6004 Repeater for four chains JB 6002...
Danish Interpretation Systems Operating instructions AO 6004 Audio Output Unit General description The AO 6004 Audio Output Unit for the DCS 6000 system enables the user to record the sound from a number of interpreted language channels or floor channel on external devices such as tape- or hard disk recorders by analogue interface.
Danish Interpretation Systems User controls, indications & connections Front plate layout The front plate layout of the AO 6004 Audio Output Unit consists of 4 XLR analogue transformer balanced outputs and 2 DCS-LAN connectors: Front plate controls and indicators The AO 6004 is an easy to use AO unit with pre- configured settings and no user interface in terms of controls, display or indicators.
Danish Interpretation Systems one of the 31 language channels or one of the three Floor channels: Floor: automatic gain controlled output Floor 1: loudspeaker unregulated audio Floor 2: loudspeaker regulated audio An ambience microphone will only be active on the Floor channel, not on Floor 1 or Floor 2 Values: {Floor 2, Floor 1, Floor, 1,…, 30, 31} The volume of the outputs can also be set if the...
Danish Interpretation Systems System Setup General guidelines Connect the AO 6004 to the various units using Cat 5 FTP or STP cables. Please observe the following guide lines: Maximum cable length in one chain is 200 without repeater. interconnection cables between the units. The max.
Danish Interpretation Systems Typical schematics Connect the AO 6004 to the DCS 6000 network using Cat 5 cables. The Analogue Audio output connectors are connected to either tape recorders Using AO 6004 with IT 6108 IR-Transmitter When using the AO 6004 with the IT 6108 Infrared Transmitter, the audio output level on the AO 6004 has to be set to match the sensitivity on the transmitter.
Danish Interpretation Systems Appendix Technical appendix Cabling CAT5 The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables with screened RJ45 connectors. EIA 568-B wiring shall be used. It is important to use only FTP or STP (screened) cables and screened RJ45 connectors and not UTP cable, which is unscreened.
Need help?
Do you have a question about the Audio Output Unit AO 6004 and is the answer not in the manual?
Questions and answers