Hobart AirForce 625 Manual page 35

Table of Contents

Advertisement

Drag Shield
204 323
Deflector
177 888
Shield
192 203
NOTE:
Set air pressure to 75 PSI for cutting
or 55 PSI for gouging.
ICE–40C
CONSUMABLES
To maintain the factory original performance of your equipment, use only Manufacturer's Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
For extended tip use, set Amperage control to 35.
Retaining Cup
Tip
192 050
204 325
Retaining Cup
35A Tip
192 050
192 052
Retaining Cup
Tip
192 050
204 332
FAILURE TO REPLACE WORN TIP OR
ELECTRODE WILL RUIN TORCH AND
VOID WARRANTY.
S Turn off power before checking torch parts.
S Check before each use and hourly during operation.
Figure 6-3. Consumable Parts For ICE-40C
Electrode
Swirl Ring
192 047
192 049
Standard
Cutting
Electrode
192 048
Extended
Cutting
—1/8" (3 mm)
standd–off
recommended
Electrode
192 047
Gouging
CAUTION
O–Ring
169 232
Apply silicone
grease (169 231)
before installing.
211 120–A
OM-926 Page 31
211 120-A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents