Semacon S-530 Operating Manual page 9

Coin sorter / value counter
Table of Contents

Advertisement

Setting the BATCH LIMITS
When using batch mode, BATCH LIMITS must be set previously. All
machine totals must be zero in order to set the BATCH LIMITS.
To set the BATCH LIMITS, press the BATCH LIMIT button so it is
illuminated. Use the COIN SELECT button to select the coin
denomination. Use the TAB button to select the digit on the display
to be set and use the UP button to increase the digit value. When the
desired limit is selected, press the STORE button to save the limit
and the display will step to the next denomination.
Note: BATCH LIMITS may be set from 1 to 30,000.
Note: BATCH LIMITS must be set when using the drawers included
with the sorter to prevent the drawers from overfilling. The BATCH
LIMITS for drawers should be set as follows:
Pennies: 150
Nickels:
80
Dimes:
250
Quarters: 200
Dollars:
80
When a BATCH LIMIT is Reached
When a BATCH LIMIT is reached during counting, the machine will
stop automatically and the coin indicator lamp corresponding to the
denomination which has reached its limit will be illuminated. The
bag, package or drawer should be replaced or emptied at this time. If
desired, the BATCH LEVEL can be cleared manually or use the
AUTO CLEAR mode to clear the full BATCH LEVELS automatically.
Displaying the BATCH LEVELS
When the BATCH LEVEL button is pushed, the BATCH LEVELS will
be displayed. Use the COIN SELECT button to display each
denomination.
Clearing Counts
CURRENT COUNT
Press the CLEAR button while in CURRENT COUNT mode (the
CURRENT COUNT button is illuminated).
GRAND TOTAL
Press the CLEAR button while in GRAND TOTAL mode (the
GRAND TOTAL button is illuminated).
BATCH LEVEL
Press the CLEAR button while in BATCH LEVEL mode (the
BATCH LEVEL button is illuminated).
Note: After pressing the CLEAR button the control panel will flash
and you must press the CLEAR button again in order to clear the
selected count(s). If you do not wish to clear the selected
count(s), press the CURRENT COUNT button while the control
panel is flashing.
Note: To clear all machine totals (MASTER CLEAR), press the
CLEAR button for four seconds then a second time when the
control panel flashes.
Auto Clear Function
When a BATCH LIMIT is reached (bag, package or drawer full)
and the batch is removed (bag, package or drawer replaced or
emptied) the BATCH LEVEL may be cleared manually or
automatically. If the AUTO CLR button is pressed and
illuminated, the machine will clear this total automatically after
the BATCH LIMIT is reached and the sorter is restarted.
Other Functions
Auto Stop Function
1. When there is no change in the coin counts for three
seconds while counting, the sorter will stop for one second
and then restart again.
2. This will be repeated three times and then the motor will stop
if there is no change in the coin counts.
Cover Open Stop Function
1. When the hopper cover or sorter cover is open, the sorter
will not move even when the MOTOR button is pressed.
The cover open indication
the display.
2. If the hopper cover or sorter cover is opened during counting,
the motor will stop and the cover open indication will appear.
To restart operation, press the MOTOR button after closing the
open cover.
8
will appear on

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents