2.0 IMPORTANT INSTALLATION POINTS
2.1 The Heatstore Ultima Profile Eco must be vertically wall mounted using the
bracket supplied.
2.2 Fig.1, p6 details the outside dimensions of the unit. It is recommended
that the unit is positioned above the draining board. If this is not possible,
consideration should be given to any spillages that may occur under the
appliance. The heater should be positioned at a height to suit the items
being filled (flasks, pans, cups etc.). This is likely to position the base of the
unit 250mm above the work surface.
2.3 Sufficient room should be left around the heater to allow access for
maintenance and servicing. The top should not be covered as this will reduce
the efficiency of the unit.
2.4 Ensure that the wall can support the full weight of the unit (see technical
specifications, p3) and that there are no hidden services (electricity, gas or
water) below the surface of the wall.
2.5 Using the backplate mark the fixing positions and water and vent entry
points. Drill and plug the fixing positions. Fix the mounting bracket to the
wall using the two No. 12 x 2" screws provided (confirm suitability of all
screws and plugs for use with the wall, if unsuitable due to wall type provide
alternative fixings)
2.6 If rear entry services are to be used the necessary holes for these should be
prepared prior to hanging the unit onto its bracket.
2.7 Remove the front cover by unscrewing the top and bottom cover fixing screws
bottom and top. Hang the unit onto the wall mounting bracket. Secure anchor
point to the wall with the No.8 x 1" screw (provided).