Sony DAV-DZ555K Operating Instructions Manual page 21

Hide thumbs Also See for DAV-DZ555K:
Table of Contents

Advertisement

Note
• When the wireless kit WAHT-SD1 (not
supplied) is installed, [STANDARD
(WIRELESS)] appears instead.
10
Press
.
11
Connect the calibration mic to the
A.CAL MIC jack on the front panel and
press X/x to select [YES].
Set up the calibration mic at the ear level
using a tripod, etc. (not supplied). The front
of each speaker should face the calibration
mic, and there should be no obstruction
between the speakers and the calibration
mic. Be quiet during the measurement.
AUDIO IN / MIC 1 /
A.CAL MIC
Calibration mic
12
Press
.
AUTO CALIBRATION
Connect calibration mic. Start
measurement?
YES
NO
Auto Calibration starts.
Note
• Loud test sound is output when [AUTO
CALIBRATION] starts. You cannot turn the
volume down. Give consideration to children
and neighbor.
• Avoid being in the measurement area and
making noise during the measurement (which
takes about 3 minutes), as it may interfere with
measurement.
13
Unplug the calibration mic and press C/
c to select [YES].
Measurement complete.
FRONT L :
YES
FRONT R :
YES
CENTER :
NONE
SUBWOOFER :
YES
SURROUND L :
NONE
SURROUND R :
NONE
If OK, unplug calibration mic and select
"YES".
YES
Note
• The environment of the room in which the
system is installed may affect measurements.
• If measurement fails, follow the message then
retry [AUTO CALIBRATION].
• When you select [SECOND ROOM] for
[SPEAKER FORMATION], measurement of
[SURROUND L] and [SURROUND R] is not
displayed.
14
Press
.
Quick Setup is finished. All connections
and setup operations are complete.
To quit the Quick Setup
Press
DISPLAY in any Step.
NO
continued
21
GB

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dav-dz556kbDav-dz750k

Table of Contents