PARAMETERS
:
o PRECISION: you can choose the timing precision between 1 sec to 1/100'000th of second. The
LCD display will show a maximum precision of 1/1'000
memorized and printed are at the specified precision.
LOCK
TIME: Lock-out time of the 4 inputs is selectable from 0.01 to 99.99 seconds. To enter
o
1.00 sec, press 1 – 0 – 0 and confirm with ◄┘.
The minimum lock-out time of 0.01 sec should not be used with any mechanical triggering device
(bounce may cause several impulses).
o INPUT STATUS
Selection of Inputs and their timing info functions info (transmit / received)
UP Narrow: TRANSMIT
DOWN Narrow: Received
HORIZONTAL: Close
The default status of the input is set as « Transmit » (after switching off)
CAPTURE
WINDOWS: (only into the Training mode)
o
The time window (min / max) automatically identifies the competitor number as he passes
through the various timing points while his run is in progress.
If the value is defined at 0, no restrictions are activated there is no guaranty that the competitor
will be correctly identified.
o BEEP: Audio Signal activation (ON/OFF). The last setting is memorized.
RS232
PC: Baud rate is selectable (2400 / 9600 / 38'400 / 57'000 and 9'600 Bds Select "Flow
o
Control" for our radio Data / Voice transmission HL 680.
RS232 AUX
: Data bus RS232 "PRINTER"
o
TO PRINTER : printer (ON/OFF)
TO AUX: Serial bus RS232 PRINTER is setup for Master/Slave mode.
To HL970/HL980: will send information to a display, including Net Time (especially for the
Training Mode) – only for the training Mode
Running Time on the TAG Heuer display
Running Time of Day of the HL 440
Blank command to the Display
Running time is the default setting
Display Duration of net times is adjustable from 1 to 59 seconds using the
Less arrows, then validate with
o LANGUAGE: The Minitimer is programmed in English , German, French and Italian
o STATUS: Capacity of the memory available, number of runs memorized and battery status in %.
PRINT
SETTING: print the full parameter settings of your Minitimer, including memory status,
o
timing mode, precision and input lock time.
PRINTER:
PRINTER
OFF: No output available. Serial bus is closed.
o
PRINTER
ON: Times and Data are send to the Serial « Printer » connection.
o
IMPORTANT
When you turn on the Printer, all saved data will be printed.
th
of second, however, all times transferred,
◄┘
(10 seconds is the default setting).