Only Compressor Does Not Run - Sanyo SAP–K91AHA Technical & Service Manual

Table of Contents

Advertisement

9-3-4. Only outdoor fan does not run.
• Check fan rotation.
Turn fan gently once or twice by
hand.
• Measure resistance of outdoor fan
motor winding.
• Check fan motor capacitor.

9-3-5. Only compressor does not run.

• Check compressor motor
capacitor.
• Measure resistance of
compressor motor winding.
• Measure Power supply
voltage.
The voltage is too low.
• Measure coil resistance of
power relay.
Fan cannot
be turned.
OK
Overload relay is working.
(C1)
Temperature of compressor
is abnormally high.
Refrigerant gas shortage.
No
Rotor may be locked up.
• Check fan casing
foreign matter on
inside.
Fan motor burnout
or foreign matter in
bearings.
(Either OLR T or OLR A)
YES
YES
NO
43
Remove foreign
matter or repair.
Repair or replace.
YES
Charge refrigerant gas (R22).