Installation Diagram Of Indoor And Outdoor Units - Toshiba RAS-B10SKVP-E Installation Manual

Hide thumbs Also See for RAS-B10SKVP-E:
Table of Contents

Advertisement

2 INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS

The indoor unit shall be
installed so that the top of the
indoor unit is positioned at
least 2 m high. Also, avoid
putting anything on the top of
the indoor unit.
2 m or more
b Wireless remote controller
Air filters
d Remote controller holder
g Remote
controller holder
mounting screw
Before installing the wireless
remote controller
• With the remote controller
cover removed, correctly
load the supplied batteries
while observing their
polarity.
b Wireless remote controller
Cover
c Batteries
• If the system will be used in cooling mode when the outdoor temperature is below zero, take measures to ensure that the
drain water does not freeze.
• When the outdoor unit is installed in a place that is always exposed to strong winds like on the coast or on a high story of
a building, secure the normal fan operation using a duct or a wind shield.
When using a multi-system outdoor unit, refer to the installation manual provided with the model
concerned.
Hook
140 mm or
more
Hook
e Plasma pure filter
80 mm or more only
when unobstructed to
the front and both sides
In principle,
leave open
(C)
100 mm or
more from
wall
200 mm or
more
(B)
When installing the
outdoor unit, leave
open in at least two
of directions (A),
Ensure sufficient
(B), (C) and (D)
space to allow
shown in the right
drainage
figure.
47 mm or more
a Installation
Hook
plate
74 mm or
more
f Mounting screw
Z
Shield pipe
(for extension
drain hose)
Y
50 mm or more
from wall
As shown in the
figure, position
power cord and
(D)
connecting
cable
downward, and
lead out along
piping
connection port.
(A)
250 mm or
more from wall
power cord
Extension drain hose
3
For the rear left and left
piping
Wall
Insert the cushion between
the indoor unit and wall, and
tilt the indoor unit for better
installation work.
Do not allow the drain hose
to become slack.
Cut the piping
hole slightly
sloped
Make sure the drain hose is
sloped downward.
The auxiliary piping can be
connected at the left, rear
left, rear right, right, bottom
right or bottom left as shown
below.
Right
Rear
Left
Rear left
right
Bottom right
Bottom left
Insulate the refrigerant pipes
separately, not together.
6 mm thick heat resisting
polyethylene foam
EN

Advertisement

Table of Contents
loading

Table of Contents