Panasonic CS-LE9NKD Service Manual page 32

Table of Contents

Advertisement

● If the set value is exceeded again within 30 seconds, the operation will restart after one minute.
● If this condition repeats continuously for seven times, all indoor and outdoor relays will be cut off.
● Error code [F99] will be displayed.
1.
Overheating protection control
When the IPM temperature rises to 120 ℃ , compressor will stop immediately.
Compressor restarts after three minutes if the temperature decreases to 110℃
13.1.5 Compressor Overheating Prevention Control
Instructed frequency for compressor operation will be regulated by compressor discharge temperature. The change of
frequency is as below.
CS/CU-LE9NKD
13.1.6 Low Operation Frequency Protection Control
When the compressor operation frequency is lower than 24Hz and continuing for 240 minutes, the operation
frequency will be changed to 23Hz for 2 minutes. This is to prevent the compressor running in too low frequency for
long time.
If all following conditions are fulfilled, the compressor will run in frequency of 30 Hz .
Models
Intake Air Temp.
Outdoor Temp.
Indoor Piping Temp.
Operation Mode
13.1.7 Low pressure Prevention control (Gas Leakage Detection)
a. Control start conditions
• For 5 minutes, the compressor continuously operates and outdoor total current is between 0.83A and 1.05A.
• During Cooling and Soft Dry operations:
Indoor suction temperature – indoor piping temperature is below 4℃.
Indoor temperature and outdoor temperature is 30±5℃.
Remote Control setting 16℃ and Hi Fan Speed.
• During Heating operations:
Indoor piping temperature – indoor suction is under 5℃.
Indoor temperature and outdoor temperature is 20 ± 2℃.
Remote control setting 30℃ and Hi Fan Speed.
b. Control contents
• Compressor stops (and restart after 3 minutes)
• If the conditions above happen 2 times within 20 minutes, the unit will:
- Stop operation
- Timer LED blinks and "F91" indicated
LE9NKD, LE12NKD
≥30 ℃ or <14 ℃
≥28 ℃ or <14 ℃
≥38 ℃ or <16 ℃
≥24 ℃ or <4 ℃
<30 ℃
Cool / Dry
CS/CU-LE12NKD
≥0 ℃
Heat
32