Maintenance
WARNING
Before performing any maintenance on gun, read all warnings on front
cover of this manual and relieve pressure.
Cleaning/Replacing Filter (6)
1.
Relieve pressure. Set trigger lock
2.
Disconnect fluid hose from gun at swivel (5).
3.
Disconnect trigger guard (4) from guard retainer (22).
4.
Unscrew handle (23) from gun (1).
5.
Remove filter (6) through top of handle (23).
6.
Clean filter (6). Use a soft brush to loosen and remove excess
debris.
7.
Insert clean filter (6) into handle (23).
8.
Reattach handle (23) to gun (1). Tighten securely.
9.
Reconnect trigger guard (4) to guard retainer (22).
Translated Manuals
French - 312831
Estonian - 312845
Spanish - 312832
Latvian - 312846
Dutch - 312833
Lithuanian - 312847
German - 312834
Polish - 312848
Italian - 312835
Hungarian - 312849
Turkish - 312836
Czech - 312850
Greek - 312837
Slovakian - 312851
Croatian - 312838
Slovenian - 312852
Portuguese - 312839
Romanian - 312853
Danish - 312840
Bulgarian - 312854
Finnish - 312841
Chinese - 312855
Swedish - 312842
Japanese - 312856
Norwegian - 312843
Korean - 312857
Russian - 312844
Translated manuals can be requested through a distributor
or at www.graco.com.

Technical Data

Maximum working pressure
Fluid orifice size
Weight (with tip and guard)
Inlet
Maximum material temperature
Wetted Parts
*Noise Level: Sound power
Sound pressure
*Measured at 3.1 ft (1m) while spraying water-based paint, specific gravity 1.36, through a 517 tip at 3000 psi (207 bar, 20.7 MPa) per ISO 3744
For complete warranty information contact your local Graco distributor, call Graco customer service:
All written and visual data contained in this document reflects the latest product information available at the time of publication.
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2008, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
3600 psi (248 bar, 24.8 MPa)
0.125 in. (3.18 mm)
22 oz. (630 g)
120 F (49 C)
Stainless steel, polyurethane, nylon, aluminum, tungsten carbide, brass
87 dBa
78 dBa
1-800-690-2894 or visit our website: www.graco.com.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents.
This manual contains English. MM 312830
r i g i n a l i n s t r u c t i o n s .
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
www.graco.com
Revised July 2014
Repair
Replacing Needle
1
15b
15a
16
WARNING
1.
Relieve pressure. Set trigger lock.
2.
Remove tip (26) and guard (25) from gun (1).
3.
Disconnect fluid hose from gun at swivel (5).
4.
Squeeze trigger while unscrewing diffuser.
5.
Remove locknut and end cap.
6.
Tap out needle.
7.
Use a soft brush to clean out internal passages of gun.
8.
Grease o-rings of new needle using a non-silicon grease.
9.
Guide new needle (15b) through front of gun .
10. Install end cap and locknut, loosely.
11. For needle housing (15a), apply medium strength (blue) thread
sealant to threads.
12. Squeeze trigger while installing needle housing. Torque to 26-32
ft-lb (35-43 N•m).
13. Hold gun with nozzle facing up.
14. Set trigger lock.
15. Turn locknut (a) clockwise until you see and feel trigger (3) raise
slightly.
16. Turn locknut (a) 3/4 turn counter-clockwise.
NOTE: When needle is properly adjusted, trigger will move freely.
17. Connect fluid hose. Install tip (26) and guard (25).
18. Prime sprayer. See sprayer instruction manual.
19. Trigger gun into bucket until fluid flows from gun.
20. Release trigger (3). Fluid flow should stop immediately.
21. Set trigger lock.
22. Aim gun into bucket. Trigger gun. No fluid should flow.
23. If the gun fails tests, steps 19 and/or 21, relieve pressure and
disconnect hose. Readjust needle. Repeat tests.