5. Protection Pass Mode
5.1. Actions
• This mode allows the power to be turned on without activating protections.
• This is the same as normal power-on, except that protections are not activated.
5.2. Operations
AVR-X2100W
· Hold down buttons "TUNER PRESET CH +", "ZONE2 SOURCE" and "STATUS" at the same time and press the power
button to turn on the power.
AVR-S900W
· Hold down buttons "ZONE2 SOURCE", "TUNER PRESET CH +" and "TUNE +" at the same time and press the power
button to turn on the power.
The device returns to the normal display after the following is displayed.
FLD
P r o t e c t i o n
This is displayed for 5 seconds before returning to the normal display.
6. CX870 / CY920 Reboot mode
6.1. Actions
• The CX870 / CY920 is restarted after CX870 / CY920 hangup.
• The CX870 / CY920 can be restarted even in the network standby setting ("Setup menu" – "Network" – "Network" –
"Always On").
6.2. Operations
1.
Turn on the button "MAIN ZONE" and set NETWORK as the input source.
2.
Hold down buttons "TUNER PRESET CH +" and "TUNER PRESET CH -" for at least 3 seconds while the power is on.
3.
FL display during CX870 / CY920 reboot
FLD
N e t w o r k
4.
Returns to the normal display.
NOTE:
• The CX870 / CY920 Reboot operation is not accepted again for one minute after executing the reboot.
• Reception is prohibited during update, save and load.
P a s s
R e s t a r t
55