Tableau 11 : Dégagement Minimum, Matériaux Combustibles - CAC / BDP CVMAAR036105 Installation Instructions Manual

Multipoise oil furnace input capacities 70,000 - 154,000
Table of Contents

Advertisement

Available languages

Available languages

EMPLACEMENT
FOURNAISE
CÔTÉS
PLÉNUM D'ALIMENTATIO N JUSQU'À 6 PI DE L A FOURNAIS E
ARRIÈRE
FOURNAISE
FOURNAISE O U PL ÉNUM
DESSUS
HORIZO NTALE À LA CONDUITE PREMIE RS 6 PI
DESSOUS
FOURNAISE ( PLANCHER COMBUSTIBLE AVEC BASE † )
HORIZO NTALE O U SOUS LE TUYAU À FUMÉE
TUYAU À FUMÉE
VERTICALE, AU DESS US DU TUYAU À FUMÉE
DEVANT
FOURNAISE
Figure 12 : Modèle CVM Capacité 120
Tableau 11 : Dégagement minimum, matériaux combustibles
APPLICATION
ASCENDANT
Ø
2 .54 cm (1")
Ø
5 .08 cm (2")
5 .08 cm (2")
Ø
10.16 cm (4")
22.86 cm (9")
20.32 cm (8")
† Lorsque la base *KLASB0601DET ou **KLASB0701DET est utilisée
22
DESCENDANT HORIZONTAL
5.08 cm (2 ")
5.08 cm (2 ")
5.08 cm (2 ")
2.54 cm (1 ")
2.54 cm (1 ")
Ø
5.08 cm (2 ")
5.08 cm (2 ")
5.08 cm (2 ")
7.62 cm (3 ")
**Ø
10.16 cm (4")
1 0.1 6 cm (4")
22.86 cm (9")
2 2.8 6 cm (9")
20.32 cm (8")
60.96 cm (2 4")

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbmaaa060120

Table of Contents