The Multifuel Heater Model 6041TP/6041HF may be installed as follows:
1) A freestanding unit
The Multifuel Heater Model 6041I insert may be installed as follows:
1) In a pre-fab fi rebox (Factory Built)
2) In an existing masonry fi replace
3) As a build-in
MOBILE HOME INSTALLATION REQUIREMENTS
IN ADDITION TO THE STANDARD INSTALLATION INSTRUCTION, THE FOLLOWING
REQUIREMENTS ARE MANDATORY FOR INSTALLATION IN A MOBILE HOME:
1) Heater must be permanently bolted to the fl oor. Remove the Base Trim and bolt thru the base fl ange.
2) Heater must have permanent outside air source. (69FAK)
3) Heater must be permanently electrically grounded to the steel chassis of the mobile home.
4) All vertical chimney vent must have wall supports.
5) All exhaust systems must have a spark arrestor.
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/
Check with your local building offi cial as other codes may apply.
12
INSTALLATION CONFIGURATIONS
DO NOT INSTALL IN SLEEPING ROOM
ROOF MUST BE MAINTAINED.
WARNING
CAUTION