Valley Comfort Systems MP80 Operation & Installation Manual

Valley Comfort Systems MP80 Operation & Installation Manual

Solid fuel wood furnace for use as an add-on to electric, gas, or oil furnaces or and independent wood furnace when equipped with a blower.

Advertisement

IF THE INFORMATION IN THESE INSTRUCTIONS ARE NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR DEATH. PLEASE READ ENTIRE
MANUAL BEFORE YOU INSTALL AND USE YOUR HEATER.
INSTALLATION IS TO BE PERFORMED BY A QUALIFIED INSTALLER
This furnace can be very hot when burning.
Combustible materials, including fi re wood, must not be stored within the furnace
installation clearances or within the space required for fueling, ash removal, and
other routine maintenance operations.
Children and pets must be kept from touching the heater when it is hot.
The chimney must be sound and free of cracks. Before installing this unit,
contact the local building or fi re or other authority having jurisdiction and follow
their guidelines.
Operate only with the doors tightly closed.
Do not use an elevated grate or otherwise raise the fi re.
This furnace is designed to burn natural wood only. Higher effi ciencies and
lower emissions generally result when burning air dried seasoned hardwoods, as
compared to softwoods or to green or freshly cut hardwoods.
Do not start a fi re with chemicals or fl uids such as gasoline, engine oil, etc.
Do not burn treated wood, coal, charcoal, coloured paper, cardboard, solvents or
garbage.
Do not let the furnace become hot enough for any part to glow red.
Comply with all local codes and regulations.
Never operate a furnace that has been improperly installed.
Never operate the furnace unless you are sure the smoke pipe and chimney
are in safe condition. Flue gasses may contain carbon monoxide which is
poisonous.
Keep smoke pipe and chimney clean to prevent a chimney fi re. Inspect and
clean fl ues and chimney regularly. In the event of a chimney fi re turn down all
thermostats and close off combustion air. Call a fi re department if necessary.
Have a clearly understood plan to handle a chimney fi re.
CLEANOUT OF THE HEAT EXCHANGER, FLUE PIPE, CHIMNEY, AND
DRAFT INDUCER IF USED, IS ESPECIALLY IMPORTANT AT THE END
OF THE HEATING SEASON TO MINIMIZE CORROSION DURING THE
SUMMER MONTHS, CAUSED BY ACCUMULATED ASH.
OPERATION & INSTALLATION MANUAL
Installer: Please complete the details on the back cover and leave this manual with the homeowner.
Valley Comfort Systems Inc., 1290 Commercial Way, Penticton, BC, V2A 3H5, Canada
Phone: 250-493-7444  Fax: 250-493-5833  www.blazeking.com  info@blazeking.com
Pour la version française de nos manuels S.V.P. vous référez à notre site web: www.blazeking.com
OM-MP80 E V1.15
SAFETY INFORMATION
CAUTION:
Homeowner: Please keep these instructions for future reference.
SOLID FUEL WOOD FURNACE
For use as an add-on to electric, gas, or oil
furnaces or and independent wood furnace
when equipped with a blower.
Manufactured By
MP80
January 29, 2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MP80 and is the answer not in the manual?

Questions and answers

Summary of Contents for Valley Comfort Systems MP80

  • Page 1 Homeowner: Please keep these instructions for future reference. Manufactured By Valley Comfort Systems Inc., 1290 Commercial Way, Penticton, BC, V2A 3H5, Canada Phone: 250-493-7444  Fax: 250-493-5833  www.blazeking.com  info@blazeking.com Pour la version française de nos manuels S.V.P. vous référez à notre site web: www.blazeking.com OM-MP80 E V1.15...
  • Page 2: Table Of Contents

    APPLICABLE STANDARDS ......................8 DEFINITIONS ..........................9 _________________________________________________ 10 INSTALLATION INSTRUCTIONS INSTALLER RESPONSIBILITIES ....................10 PARTS INCLUDED WITH THE MP80 ................... 10 OPTIONAL EQUIPMENT ....................... 10 USAGE ............................. 10 CLEARANCE TO COMBUSTIBLE MATERIALS / PLENUM AND VENTING INSTALLATION .. 12 COMBUSTION AIR .........................
  • Page 3: Introduction

    Do not store the wood within appliance installation clearances or within the space required for re-fueling and ash removal. • Your appliance requires periodic maintenance and cleaning. Failure to maintain your appliance may lead to smoke spillage in your home. OM-MP80 E V1.15 January 29, 2015...
  • Page 4: Specifications

    Stainless steel baffl e system to retain high combustion effi ciency. Construction • 14 gauge fi rebox • Cast iron liners • 12 gauge heat exchanger • 20 gauge cabinet • Stainless steel baffl e Shipping Weight 325 lbs. OM-MP80 E V1.15 January 29, 2015...
  • Page 5: Appliance Dimensions

    MP80 Page 5 APPLIANCE DIMENSIONS OM-MP80 E V1.15 January 29, 2015...
  • Page 6: Product Information

    MP80 Page 6 PRODUCT INFORMATION Loading door Adjustable door latch catch Stainless steel baffl e Cast liners Damper Combustion motor air vents Combustion air fl ap Cutaway view OM-MP80 E V1.15 January 29, 2015...
  • Page 7: Certification Label

    MODEL MP-80 LISTED SOLID FUEL FURNACE THIS LABEL MADE IN CANADA BY SERIAL WH Valley Comfort Systems Inc. 1290 Commercial Way, Penticton, BC, V2A 3H5 CETTE UNITÉ PEUT ÊTRE INSTALLEE COMME INDIQUÉ CI-DESSOUS: CERTIFIED TO / CERTIFIÉE SELON: CSA Std B366.1-11 4011009 FOURNAISE INDEPENDANTE A CIRCULATION D’AIR PULSÉ...
  • Page 8: Safety Precautions

    ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH LOCAL CODES AND WITH THE CURRENT CSA C22.1 CANADIAN ELECTRIC CODE. APPLICABLE STANDARDS Certifi cation Standards and Installation Codes: UL391-2010 UL 1995-2005/CSA C22.2 NO .236-05 CSA B-139-10 CSA B-365-10 CSA B-366.1-11 OM-MP80 E V1.15 January 29, 2015...
  • Page 9: Definitions

    Combination appliance---an appliance that is certifi ed to operate with multiple types of fuels. Be it resolved that because of their nature; Solid fuel burning Combination furnaces and fully assembled Add-on furnaces are to be installed as per the Manufacturers’ Certifi ed Instructions. OM-MP80 E V1.15 January 29, 2015...
  • Page 10: Installation Instructions

    2. CF6 kit for use in wood counter fl ow installations (see Fig. “D” on next page). USAGE Th e MP80 may be installed as follows (see Fig.3 “INSTALLATION INSTRUCTIONS cont. ” on page 11) 1. An add-on to any of the following furnaces: a.
  • Page 11 MP80 Page 11 INSTALLATION INSTRUCTIONS cont. CERTIFIED FOR INSTALLATION WITH THE FOLLOWING DUCTWORK CONFIGURATION(S) ONLY CF6 KIT Fig. 3 Typical installation illustration OM-MP80 E V1.15 January 29, 2015...
  • Page 12: Clearance To Combustible Materials / Plenum And Venting Installation

    Chimney draft to be a minimum -0.03” W.C. (-10 Pa) to maximum -0.06” W.C. (-15 Pa). OM-MP80 E V1.15 January 29, 2015...
  • Page 13 Th is fl oor protection is required to prevent sparks from falling onto the combustible fl oor. See CSA B365-M87. It is not required to be a heat protective covering. This furnace must be installed in compliance with all local codes and regulations. OM-MP80 E V1.15 January 29, 2015...
  • Page 14: Combustion Air

    Page 14 INSTALLATION INSTRUCTIONS cont. NOTE: AFTER INTERCONNECT DUCT OPENING HAS BEEN CUT INTO THE SIDE OF THE MP80, INSULATION MUST BE FASTENED BACK TO THE FURNACE CABINET ALL AROUND THE OPENING. USE THE METAL STRIPS PROVIDED TO HOLD THE INSULATION TIGHTLY AGAINST THE CABINET INSIDE, TO PREVENT THE INSULATION FROM DISLODGING DUE TO BLOWER INDUCED VIBRATION.
  • Page 15: Fan Limit Installation

    Advise the homeowner to check the fi t of the door gasket from time to time to ensure a seal all around the fi rebox door. A loose fi tting door will allow entry of excess air and result in higher burn rates with less control. OM-MP80 E V1.15 January 29, 2015...
  • Page 16: General Considerations For Add-On To Gas/Oil/Electric Furnaces

    ADD-ON TO ELECTRIC FURNACE Th e MP80 may be added to an electric furnace with heating capacity between 10KW and 25KW. Minimum blower capacity must be at least 900 cfm. Electric furnaces approved for installation in any position can be inverted and used in a down fl ow position using an adapter duct between the furnace and the add-on as indicated in Fig.3 (see “INSTALLATION INSTRUCTIONS cont.
  • Page 17 MP80 Page 17 INSTALLATION INSTRUCTIONS cont. Fig. 21 ELECTRICAL CONNECTIONS WOOD/ELECTRIC WITH R AND G CONNECTIONS OM-MP80 E V1.15 January 29, 2015...
  • Page 18: Add-On To Gas Furnace

    ADD-ON TO OIL FURNACE Th e MP80 may be connected to an oil furnace having a rated input of up to 1.2 USGPH. Minimum blower capacity must be at least 900 cfm. A regular up fl ow oil furnace may be used and connected as per Fig.3 (see “INSTALLATION INSTRUCTIONS cont.
  • Page 19 Th e words and letters marked on the switches and relays should be followed and connections made to the proper locations. WIRING DIAGRAM FOR THE CONNECTION OF THE MP80 TO AN ALTERNATIVE GAS OR OIL FURNACE WITH 120 VAC FAN CONTROL.
  • Page 20 INSTALLATION INSTRUCTIONS cont. INDEPENDENT WOOD FURNACE When installed with a blower cabinet mounted on either side, the MP80 becomes an INDEPENDENT wood only furnace. Th e blower must have a minimum 900 cfm. capacity (1/3 hp.). In this confi guration the interlock limit is not used. Figure 23 shows the electrical connections.
  • Page 21: Stand Alone Installation

    STAND ALONE INSTALLATION When the MP80 is used as an independent furnace a blower with a minimum of 900 cfm and a maximum of 1200 cfm is required. Th e VB1000 blower is built by Valley Comfort for the following models: Blaze King Apex CBT, Valley Comfort MP80 &...
  • Page 22: Operating Instructions

    5° F (3°C) lower. NOTE: IF THE ALTERNATIVE FURNACE IS RUNNING AND THE WOOD FURNACE IS STARTING TO HEAT UP AFTER RE-LOADING, THE ALTERNATE FURNACE WILL SHUT OFF AUTOMATICALLY. OM-MP80 E V1.15 January 29, 2015...
  • Page 23: Fan Operation

    AND IGNORING LEAKING GASKET CAN RESULT IN EXTREME OVER FIRING CONDITIONS. • RISK OF FIRE OR EXPLOSION - DO NOT BURN GARBAGE, GASOLINE, DRAIN OIL, NAPHTHA, ENGINE OIL OR OTHER FLAMMABLE LIQUIDS. OM-MP80 E V1.15 January 29, 2015 Janu nuar ary...
  • Page 24: Inspection Of Flues And Chimneys

    Dispose of ashes in an airtight, metal container and store it outside and away from combustibles. COMBUSTION AIR VENTS MUST NOT BE OBSTRUCTED (see diagram ”PRODUCT INFORMATION” on page 6) OM-MP80 E V1.15 January 29, 2015...
  • Page 25: Maintenance

    If accumulation is excessive, clean the chimney. You may want to call a professional chimney sweep to clean it. Both the chimney and the appliance have to be cleaned at least once a year or as oft en as necessary. Have a clearly understood plan to handle a chimney fi re. OM-MP80 E V1.15 January 29, 2015...
  • Page 26: Fire Extinguishers And Smoke Detectors

    Firewood should be split and stacked in a manner that air can get to all parts of it and covered in early spring to be ready for burning that fall. OM-MP80 E V1.15 January 29, 2015...
  • Page 27 Th e purpose of door gasketing is to seal the fi rebox. If the door is not sealed, air leaks into the fi rebox, creating a quick burning fi re. Th is situation is not desirable for overnight or extended burns. Refer to your Valley Comfort dealer regarding gasket replacement. OM-MP80 E V1.15 January 29, 2015...
  • Page 28: Replacement Parts

    0517 Fan Limit Adjustable 8008 Stainless Steel Baffle dmpmtr Damper Motor KS10 VC95 & MP80 Cast Piece KS13 VC95 & MP80 Cast Piece VC95 & MP80 Cast Piece KS8LH VC95 & MP80 Cast Piece KS8RH VC95 & MP80 Cast Piece VC95 &...
  • Page 29: Warranty

    Firebox & Heat Exchanger, Bypass 5 Years 2 Years Door Steel Components Catalyst Combustor ( see 6 Years Conditions, Exclusions, and Limitations) 1 Year Other Replacement Parts See Conditions, Exclusions, and Limitations OM-MP80 E V1.15 January 29, 2015...
  • Page 30 If you are not satisfi ed with the service provided by the Blaze King dealer, write to Blaze King at the address listed on the last page of the Owner’s Manual. Include a copy of the original purchase invoice and a description of the problem. OM-MP80 E V1.15 January 29, 2015...
  • Page 31 17. Blaze King is free of liability for any damages caused by the stove, as well as inconvenience expenses and materials. The Limited Warranty does not cover incidental or consequential damages. OM-MP80 E V1.15 January 29, 2015...
  • Page 32 33. Blaze King is responsible for stocking parts for a maximum of seven (7) years after discontinuing the manufacture or incorporation of the item into its products. An exception to this would be if an OEM supplier is not able to supply a part. OM-MP80 E V1.15 January 29, 2015...
  • Page 33: Installer Notes

    I CERTIFY THAT I HAVE INSTRUCTED THE HOMEOWNER ON PROPER FIREWOOD HANDLING: Installer: Please complete the following information Dealer Name & Address:________________________________________________________ ____________________________________________________________________________ Installer (print): _______________________________________________________________ Installer (sign): _______________________________________________________________ Phone #: ____________________________________________________________________ Date Installed:_________________________________________________________________ Serial No.: ___________________________________________________________________ OM-MP80 E V1.15 January 29, 2015...
  • Page 34: Notes

    MP80 Page 34 NOTES OM-MP80 E V1.15 January 29, 2015...