Dell PowerConnect B-DCX-4S Replacement Procedure page 11

Hide thumbs Also See for PowerConnect B-DCX-4S:
Table of Contents

Advertisement

switchId:
fffc0b
switchWwn:
10:00:00:05:1e:39:59:67
zoning:
OFF
switchBeacon:
OFF
blade3 Beacon:
OFF
blade5 Beacon:
OFF
blade8 Beacon:
OFF
blade10Beacon:
OFF
Index
Slot
Port
===========================================================
32
3
0
33
3
1
34
3
2
35
3
3
36
3
4
10:00:00:00:c9:51:00:2d
37
3
5
switch:admin>
4. Verify that all the IP address information is correct by typing ipAddrShow and checking the results against the IP
information recorded in the "config-miscinfo.txt" file.
switch:admin> ipaddrshow
SWITCH
Ethernet IP Address: 10.32.50.12
Ethernet Subnetmask: 255.55.0.0
Fibre Channel IP Address: 1.2.3.4
Fibre Channel Subnetmask: 255.255.255.0
CP0
Ethernet IP Address: 10.32.50.10
Ethernet Subnetmask: 255.55.0.0
HostName : cp0
Gateway Address: 10.32.40.1
CP1
Ethernet IP Address: 10.32.50.11
Ethernet Subnetmask: 255.55.0.0
HostName : cp1
Gateway Address: 10.32.40.1
Backplane IP address of CP0 : 10.0.0.4
Backplane IP address of CP1 : 10.0.0.5
switch:admin>switch:admin>
Reconnecting the system to the network and fabric
See the cable routing information recorded in
1. Connect the CP blades to the local area network:
a. Insert the appropriate Ethernet cables into each Ethernet port.
b. Connect the other ends to an Ethernet 10/100 Base-T LAN, if not already connected.
PowerConnect B-DCX-4S Chassis Replacement Procedure
53-1001800-01
Address
Media
Speed
0b2000
id
N4
0b2100
__
N8
0b2200
__
N8
0b2300
__
N8
0b2400
id
N4
0b2500
__
N8
Table 2
for the following steps.
State
Proto
Online
L-Port 5 public
No_Module
No_Module
No_Module
Online
F-Port
No_Module
11

Advertisement

Table of Contents
loading

Table of Contents