Dell PowerConnect B-DCX-4S Replacement Procedure page 5

Hide thumbs Also See for PowerConnect B-DCX-4S:
Table of Contents

Advertisement

TABLE 1
Critical information checklist (Continued)
SAN profile
Location of "SANbefor.txt" file
Notes regarding nsshow output
Notes regarding nsallshow output
Notes regarding switchshow output
Notes regarding fabricshow output
Output from supportshow command
Location of "spptshow.txt" file
Notes regarding supportshow output
Information about the new chassis
New Factory Serial Number
New Serial Number (if available)
1. Open a Telnet session and log in to the PowerConnect B-DCX-4S as admin. The default password is password.
Enable the logging function on your Telnet or serial console connection.
2. Back up the current configuration.
Enter configUpload; then, enter the requested information at the prompts.
This command uploads the PowerConnect B-DCX-4S configuration to the customer-defined FTP server,
making it available for downloading. For more information about this command, refer to the Fabric OS
Command Reference.
switch:admin> configupload
Protocol (scp or ftp) [ftp]: ftp
Server Name or IP Address [host]: 123.123.123.123
User Name [user]: Admin24
File Name [config.txt]: config-switch0.txt
Password: xxxxxxxx
Upload complete
switch:admin>
Alternatively, you can save the configuration file to a Brocade USB.
3. Record the WWN value: Enter wwn; then, copy the command output into a file named "config-miscinfo.txt" on a
workstation.
switch:admin> wwn
10:00:00:60:69:00:00:0a
4. Record the IP address information.
Enter ipAddrShow -sw; then, copy the command output into the "config-miscinfo.txt" file on a workstation.
switch:admin> ipaddrshow
SWITCH
Ethernet IP Address: 10.32.50.12
Ethernet Subnetmask: 255.55.0.0
Fibre Channel IP Address: 1.2.3.4
Fibre Channel Subnetmask: 255.255.255.0
PowerConnect B-DCX-4S Chassis Replacement Procedure
53-1001800-01
5

Advertisement

Table of Contents
loading

Table of Contents