Innovative Energies YK-PSW122KVA User Manual

Pure sine wave inverter yk- psw2kva series

Advertisement

Quick Links

YK- PSW2KVA Series
Pure Sine Wave Inverter
User Manual
YK-PSW122KVA/E
YK-PSW242KVA/E
YK-PSW482KVA/E
YK-PSW1102KVA/E
YK-PSW2202KVA/E
Innovative Energies Ltd. 1 Heremai Street, Henderson NZ.
Tel: +64 9 835 0700. info@innovative.co.nz. www.innovative.co.nz
-mount Model

Advertisement

Table of Contents
loading

Summary of Contents for Innovative Energies YK-PSW122KVA

  • Page 1 -mount Model YK- PSW2KVA Series Pure Sine Wave Inverter User Manual YK-PSW122KVA/E YK-PSW242KVA/E YK-PSW482KVA/E YK-PSW1102KVA/E YK-PSW2202KVA/E Innovative Energies Ltd. 1 Heremai Street, Henderson NZ. Tel: +64 9 835 0700. info@innovative.co.nz. www.innovative.co.nz...
  • Page 2: Table Of Contents

    List of Contents 1. Features Application Electrical performance Mechanical drawings 2. Introduction Front panel operations Rear panel operations Installation Quick hook – up and testing AC safety grounding Making DC wiring connections Inverter operation Cooling fan working code 3. Maintenance 4.
  • Page 3: Features

    1. Features ! Pure sine wave output (THD < 3%) R Load ! By pass function ! Output frequency : 50 / 60Hz switch ! RS – 232 interface / remote controls port / Wire connection to PC ! Wired Remote control ! Load controlled cooling fan ! Advanced microprocessor ! Protection : Input Undervoltage...
  • Page 4: Electrical Performance

    1-2 Electrical Performance Specification Model YK-PSW YK-PSW YK-PSW YK-PSW YK-PSW YK-PSW YK-PSW YK-PSW YK-PSW YK-PSW Item 122KVA 242KVA 482KVA 1102KVA 2202KVA 122KVA 242KVAE 482KVAE 1102KVAE 2202KVAE (2U) (2U) (2U) (2U) (2U) E(2U) (2U) (2U) (2U) (2U) Continuous Output 2000W Power 3Min 2300W Surge Rating...
  • Page 5: Mechanical Drawings

    1-3 Mechanical Drawings...
  • Page 6: Introduction

    2. Introduction: The power inverter series are the member of the most advanced line of mobile AC power systems available. To get the most out of the power inverter, it must be installed and used properly. Please read the instructions in this manual before installing and using this model. 2-1 Front Panel Operation: 2-1-1 Front view: 2-1-2 ON / OFF switch:...
  • Page 7: Rear Panel Operations

    2-2 Rear Panel Operation: 2-2-1 Ventilation openings: Do not obstruct, allow at least 3 inch for air flow. 2-2-2 AC input switch: This switch is to be operated by qualified personnel only. 2-2-3 Battery terminals: Connect to 12V / 24V / 48V battery or other 12V / 24V / 48V power Source. is positive, is negative.
  • Page 8 WARNING! Any damages caused by using incorrect RS232 cable will be outside of our warranty scope. If you are not sure which one is correct RS232 cable, please purchase the correct RS232 cable from us directly. 2-2-5 Connect chassis ground terminal to earth or to vehicle chassis using # 8 AWG wire. WARNING! Operation of the inverter without a proper ground, connection may result in an electrical safety hazard.
  • Page 9: Installation

    2-3 Installation: Where to install; The power inverter should be installed in a location that meets the following requirements. 2-3-1 Dry – Do not allow water to drip or splash on the inverter. 2-3-2 Cool – Ambient air temperature should be between -20 and 50 , the cooler the better.
  • Page 10: Ac Safety Grounding

    WARNING! Make sure all the DC connections are tight (torque to 9-10 ft-lbs, 11.7-13Nm). Loose connections will overheat and could result in a potential hazard. 2-4-3 Before proceeding further, carefully check that cable you have just connected negative terminal of inverter to the negative output power source. CAUTION! Reverse polarity connection will blow a fuse in inverter and may permanently damage the inverter.
  • Page 11: Making Dc Wiring Connections

    2-5-1 Neutral Grounding (GFCI’s): 2-5-1-1 120V models: The neutral conductor of the AC output circuit of the Inverter is automatically connected to the safety ground during inverter operation. According to national electrical code requirements that separately derived AC sources (such as inverter and generators) have their neutral conductors tied to ground in the same way that the neutral conductor from the utility is tied to ground at the GFCI breaker panel.
  • Page 12: Inverter Operation

    Increasing your DC cable size will help improve the situation. Our company recommends the following cables for optimum inverter performance (apply both 120V and 230V versions) Model No Wire AWG Inline Fuse YK-PSW122KVA #2/0 250A YK-PSW122KVAE YK-PSW242KVA #1/0 125A...
  • Page 13 DC Input over DC Input over DC Input under DC Input under Model voltage shut-down voltage alarm voltage alarm voltage shut-down YK-PSW122KVA 16.0VDC 15.5VDV 10.5VDC 10.0VDC YK-PSW122KVAE YK-PSW242KVA 32.0VDC 31.0VDC 21.0VDC 20.0VDC YK-PSW242KVAE YK-PSW482KVA 62.0VDC 61.0VDC 43.0VDC 42.0VDC YK-PSW482KVAE YK-PSW1102KVA...
  • Page 14: Cooling Fan Working Code

    Please have the accuracy of 6 functions of display, as below: Function WATT TEMP Frequency 100-120 200-240 10-16 20-32 42-62 90-140 180-275 Range 0-20A 0-2KW 0-50 °C 50Hz 60Hz Accuracy ± 1% ± 1% 1% ± 0.5A ± 3% ± 2% ± 2% ± 2% ± 2% ±...
  • Page 15: Maintenance

    3. Maintenance: Very little maintenance is required to keep your inverter operating properly. You should clean the exterior of the unit periodically with a dry cloth to prevent accumulation of dust and dirt. At the same time, tighten the Screws on the DC input terminals.
  • Page 16: Warranty

    5. Warranty : We warrant this product against defects in materials and workmanship for a period of 12 months from the date of purchase and will repair or replace any defective power inverter when directly returned (postage paid) to us. This warranty will be considered void if the unit has suffered any obvious damage by natural and man-made factors or alteration either internal or external and does not cover damage arising from improper use such as plugging the unit into an unsuitable power sources...
  • Page 17: Precautions When Working With Batteries

    240 VAC The VAC value will gradually increase if tune VR from right to left. RE-MARK: The user manual is subject to change without notice. Innovative Energies Ltd. 1 Heremai Street, Henderson NZ. Tel: +64 9 835 0700. info@innovative.co.nz. www.innovative.co.nz...